Specifications

Back-UPS Pro 500 BG500 120 Vac 33
Energy Management
Path: UPS > Energy Management
Energy Management Settings
UPS Location. You can change the default
UPS Location, by choosing an option from the
drop-down box. Changing the location affects
the cost and energy usage displayed.
By clicking on edit to the right of the drop-
down box, you can manually input the location,
energy cost, CO
2
, and currency values.
Outlet Shutdown settings. Master
Standby Load Threshold.
This field sets a
value which governs when the Smart Outlets
are automatically switched off and on. (You
also have to enable Master Control Mode).
This will save you power and money. See table.
Smart Power Tracking. Using this is an alternative to inputting a value in Master Standby Load Threshold
(above). Select Smart Power Tracking to automatically establish and implement the value in the Master Standby
Load Threshold. It does this by tracking the real power of the Master outlet.
Energy Management status
Accumulated Energy Usage. This enables you to monitor the energy consumption of equipment attached to
your UPS. In addition it gives you energy-related data like your carbon dioxide emissions and your energy costs.
This field shows the total consumption in kilowatts per hour (kWh) of devices attached to all your outlets. You can
also click on energy details to display Energy Usage for Client Outlet for information on individual outlets. The
fields there are described on the following table.
When the real power of the
Master outlet...
the Smart Outlets...
<
Master Standby Load Threshold
...are switched OFF
>
Master Standby Load Threshold
plus 5 Watts
...are switched ON
bu285a