Specifications

13
For more information, visit APC’s Web site at www.apcc.com or call your local APC office
Customise your power
protection solution with
UPS Accessories* from APC
Reboot hung servers
via Web, SNMP, or Telnet
From your Network Management Station
you may use the 10Base-T Ethernet
Web/SNMP Management Card (AP9606)
and/or Token Ring (AP9603) SNMP Card.
Perform remote UPS shutdown, reboot, and
other management and diagnostic functions.
Integrate smoke or halon alarms,
telephone switches and other dry
contact closures
Add security to your UPS system with the
Relay I/O Card (AP9610).
Monitor temperature, humidity and
rack security
Smoke alarms and halon alarms can also
be monitored with the Environmental
Monitoring Card (AP9612TH) through the
PowerChute plus, PowerNet SNMP or the
Out-of-band Management Card interface.
The alarm switch kit (AP9513) is designed
to monitor and notify users (when used in
conjunction with AP9612TH and the
NetShelter
®
rack enclosure) if the
NetShelter door has been breached.
Extended UPS monitoring
The Isolated Serial Extension Cable (ISEC)
is designed to provide bulletproof
monitoring of an APC UPS for extended
distances up to100 meters (AP9825).
Reboot hung servers and networking
equipment remotely via modem
The Out-of-band Management Card
(AP9608) provides complete UPS
information, paging on power problems
and remote safe reboot of servers via user
supplied modem.
Safely shutdown up to three servers
The 2-Port Interface Expander Card
(AP9607) provides two additional ports to
facilitate graceful system shutdown via
serial connections and allows advanced
UPS management. The unit is ideal for
“server farms” or multiple operating
system environments, since all three
servers can be running different OSs.
Shutdown multiple servers from one UPS
Connect up to 8 completely OS-independ-
ent servers to a single UPS with Share-
UPS
(AP9207) 8-Port interface expander
(15 servers with 2 Share-UPS). Share-UPS
integrates with PowerChute plus software.
Each server runs its own copy of
PowerChute plus software, for monitoring
and power management of the UPS.
Integrate multiple accessories
The Triple Expansion Chassis (AP9604) is
an external, 1U, 19” rack-mountable device
that allows integration of additional UPS
slot accessories with a Smart-UPS,
Matrix, or Symmetra Power Array. Triple
Expansion Chassis can be used in a rack
environment or as a stand-alone device
that allows you to add up to three (3) slot
cards to UPSs that have an existing slot
already in use.
MasterSwitch
remote reboot device
The MasterSwitch (AP9210i) network
power controller can easily reboot remote
servers, internetworking equipment, or
banks of modems to prevent on-site s
ervice calls. The perfect complement to
your High Availability solution,
MasterSwitch gives you power distribution
and complete, remote control of eight
independent power channels to put an end
to the frustration of locked-up servers and
wasted management time.
Remote Power-off Cable
The APC Remote Power-off Device (RPO)
allows data center managers to turn off APC
UPS output with a remote switch. When
used in conjunction with an Emergency
Power-Off (EPO) system, the RPO can turn
off equipment in an emergency. (AP9830)
APC Remote
Power-off Device
Isolated Serial
Extension Cable
APC MasterSwitch
Power Controller
Triple
Expansion Chassis
(*Note: APC accessory cards are designed to
work with APC UPS products that have a
SmartSlot bay. The SU420INET and SU620INET
products do not have a SmartSlot bay.)
Accessories - Managing Smart-UPS
Out-of-band
Management
Card (AP9608)
Relay I/O Card
(AP9610)
2-port
Interface
Expander
Card (AP9607)
Environmental
Monitoring Card
(AP9612TH)
Share-UPS 8 port
interface expander
Web/SNMP
Management Card