Installation Manual UPS Network Management Card 2 AP9630, AP9631, AP9635 990-3404D-001 Publication Date: October 2015
Schneider Electric IT Corporation Legal Disclaimer The information presented in this manual is not warranted by the Schneider Electric IT Corporation to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational and site specific development plan.
This manual is available in English on the APC Web site (www.apc.com). Dieses Handbuch ist in Deutsch auf der APC Webseite (www.apc.com) verfügbar. Данное руководство на русском языке доступно на сайте APC (www.apc.com ) 本マニュアルの日本語版は APC ウェブサイト (www.apc.com) からダウンロードできます。 在 APC 公司的网站上 (www.apc.com) 有本手册的中文版。 This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Данное руководство на русском языке имеется на прилагаемом компакт-диске.
Contents Preliminary Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features ....................................... 1 Devices in which you can install the NMC 2 ............ 2 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Language Packs . . . . . . . . . . .
Command Line Interface access - Telnet, SSH and Dial-in Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Simple Network Management Protocol (SNMP) FTP and SCP . . . . . . . . 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Manage the security of your system . . . . . . . . . . . . . . . . . 20 How to Install Multiple Management Cards . . . . . . . . . . . . . . . . 21 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preliminary Information Features The Schneider Electric UPS Network Management Cards (AP9630, AP9631 and AP9635) discussed in this document are Web-based, IPv6 Ready products.
The AP9631 Network Management Card includes all AP9630 Network Management Card features and the following: • Provides two USB ports, which support upgrading the NMC 2 firmware from a USB flash drive.
* The Single or Triple Expansion Chassis are only compatible with UPS that have a DB9 serial port. They are only compatible with following UPS models: SURT, SURTA, Symmetra® Power Array/RM/LX/PX (excluding PX 250/500), SU, SUA, and SUM. To view the full list of compatible UPS in which an NMC 2 can be installed, see Knowledge Base article FA237786 on the APC website.
The quality assurance test slip contains the MAC address that you may need when performing the procedures in “Device IP Configuration Utility” on page 10. You can also find the MAC address on the bottom of your NMC 2. Disclaimer Schneider Electric is not responsible for damage sustained during reshipment of this product. The Network Management Card 2 (NMC 2) is sensitive to static electricity.
Installation in a UPS How to install the card for different UPS models To view the full list of compatible UPS in which an NMC 2 can be installed, see Knowledge Base article FA237786 on the APC website. Only the AP9635 NMC 2 can be installed in a Symmetra PX 250 or Symmetra PX 500 UPS. In a Symmetra UPS that uses more than one management product, you must install the management products in the correct order for them to operate properly. See “How to Install Multiple Management Cards” on page 21.
3. Connect a network interface cable to the 10/100Base-T network connector on the NMC 2. 60a mph 04 When the network interface cable is connected, the NMC will attempt to obtain an IP address via DHCP. See “TCP/IP configuration methods” on page 9. Step 2: Configure the Network Management Card See “Quick Configuration” on page 9.
Expansion/Triple Chassis Installation When to use an Expansion Chassis Use an Expansion Chassis or a Triple Expansion Chassis if the UPS has no card slot available. The Single (AP9600) or Triple Expansion Chassis (AP9604) are only compatible with UPS models that have a DB9 serial port. They are compatible with following UPS models only: SURT, SURTA, Symmetra® Power Array/RM/LX/PX (excluding PX 250/500), SU, SUA, and SUM.
Step 2: Install the Network Management Card If the UPS uses multiple management products, you must install them in the correct order for them to operate properly. See “How to Install Multiple Management Cards” on page 21. The UPS Network Management Card (NMC 2) is sensitive to static electricity. When handling the NMC 2, touch only the end plate while using one or more of these electrostatic-discharge devices (ESDs): wrist straps, heel straps, toe straps, or conductive shoes.
Quick Configuration Overview Disregard the procedures described in this chapter if you have StruxureWare Data Center Expert as part of your system. See the documentation for your StruxureWare device for more information.
Device IP Configuration Utility The Device IP Configuration Utility can discover Network Management Cards (NMC 2) that do not have an IP address assigned. Once discovered, you can configure the IP address settings for the cards. You can also search for devices already on the network by entering an IP range to define the search. The Utility scans the IP addresses in the defined range and discovers cards that already have a DHCP-assigned IP address.
A user configuration (.ini) file can function as a BOOTP or DHCP boot file. For more information, see the TCP/IP configuration section of the Network Management Card User’s Guide, available from the Utility CD or the APC Web site, www.apc.com.
DHCP. You can use an RFC2131/RFC2132-compliant DHCP server to configure the TCP/IP settings for the Network Management Card (NMC 2). This section summarizes the NMC’s communication with a DHCP server. For more detail about how a DHCP server can configure the network settings for a Network Management Card, see the NMC 2 User’s Guide on the Utility CD or on the website. 1.
Local access to the command line interface For local access, use a computer that connects to the Network Management Card through the serial port to access the command line interface: 1. Select a serial port at the computer, and disable any service that uses that port. 2. Connect the provided serial cable (part number 940-0299) from the selected port on the computer to the configuration port at the NMC. 3. Run a terminal program (e.g.
Remote access to the command line interface From any computer on the same network as the Network Management Card, you can use ARP and Ping to assign an IP address to the Network Management Card, and then use Telnet to access its command line interface and configure the other TCP/IP settings. After the Network Management Card has its IP address configured, you can use Telnet, without first using ARP and Ping, to access that Network Management Card. 1.
Command line interface After you log on at the command line interface, as described in “Local access to the command line interface” on page 13 or “Remote access to the command line interface” on page 14, you can manually configure network settings. 1. Contact your network administrator to obtain the IP address, subnet mask, and default gateway for the Network Management Card. 2. Use this command to configure network settings. (Text in italics indicates a variable.
UPS User Interface Display Configuration of the NMC IP address though the UPS user interface display is not available for all UPS models. For Smart-UPS model UPS with the prefix SMT, SMX, or SRT, the NMC IP address can be configured at the user interface of the UPS: 1. If you plan to manually assign the network settings, contact your system administrator to obtain a valid IP address, subnet mask, and default gateway for the Network Management Card. 2. At the user interface display, press the Home icon. 3.
How to Recover from a Lost Password You can use a local computer that connects to the Network Management Card through the serial port to access the command line interface. 1. Select a serial port at the local computer, and disable any service that uses that port. 2. Connect the provided serial cable (part number 940-0299) to the selected port at the computer and to the configuration port at the Network Management Card. 3.
How to Access a Configured Network Management Card Overview After the UPS Network Management Card (NMC 2) is running on your network, you can use the interfaces summarized here: Web interface, Telnet, SSH, Dial-in access (AP9635 only), SNMP, FTP, and SCP. For more information about the interfaces, see the User Guide. Web interface The Network Management Card 2 Web interface is compatible with: • • Windows® operating systems: – Microsoft® Internet Explorer® (IE) 8.
Command Line Interface access - Telnet, SSH and Dial-in Access You can access the command line interface through Telnet or Secure SHell (SSH), depending on which is enabled. To enable these access methods, use the NMC 2 Web interface. By default, Telnet is enabled. Telnet for basic access. Telnet provides the basic security of authentication by user name and password, but not the high-security benefits of encryption.
Use of SNMPv2c is supported by the SNMPv1 options. SNMPv3 only. For SNMP GETs, SETs, and trap receivers, SNMPv3 uses a system of user profiles to identify users. An SNMPv3 user must have a user profile assigned in the MIB software program to perform GETs and SETs, browse the MIB, and receive traps. The default settings are no authentication and no privacy. To use SNMPv3, you must have a MIB program that supports SNMPv3.
How to Install Multiple Management Cards Overview When installing more than one management card, such as the Network Management Card 2 (NMC 2), the Out of Band Management Card, etc., you must install the cards in the order described in this document. This is because they share a serial link with the UPS. Installing the cards in any other order might result in operational failure. Before you start The following table identifies the priority of the cards you will be installing.
Two models of expansion chassis If you need management card slots in addition to those in your UPS, use one or more expansion chassis available. Chassis Compatible UPS Devices Expansion Chassis (AP9600), one slot UPS devices that have a DB9 port and that are not installed in a rack or enclosure. Triple Expansion Chassis (AP9604BLK), three slots UPS devices that have a DB9 port. The Single (AP9600) or Triple Expansion Chassis (AP9604BLK) are only compatible with UPS models that have a DB9 serial port.
If the NMC is pre-installed in the UPS, refer instead to “When an NMC has been pre-installed.” on page 24. Installing cards in a Symmetra UPS For more information on Symmetra UPS models that are compatible with your NMC 2, see KBase article FA237786 on the APC support website, www.apc.com/support. If you are installing an NMC without an attached expansion chassis, install that card in the highest numbered slot, even if you are leaving other slots empty.
Probe s Sensor Zone s GND 1 2 3 4 1 2 AP9612TH Environmental Monitoring Card Management Port USB Universal I/O Universal I/O Network Status C onfig Universal I/O Universal I/O Smart Slot Network A P 963 1 N etw ork M anagement Card 2 Management Port Status C onfig R eset 10/100 Smart Slot A P 963 1 N etw ork M anagement Card 2 AP9608 Out-of-Band Management Card mph0463a USB R eset 10/100 AP9608 Out-of-Band Management Card When an NMC has been pre-installed.
Specifications AP9630, AP9631 Physical Size (H x W x D) 38.1 x 120.7 x 108.0 mm (1.50 x 4.75 x 4.25 in) Weight 0.14 kg (0.30 lb) Shipping weight 0.91 kg (2.
Specifications AP9635 Physical Size (H x W x D) 38.1 x 120.7 x 108.0 mm (1.50 x 4.75 x 4.25 in) Weight 0.14 kg (0.30 lb) Shipping weight 0.91 kg (2.
cryptlib copyright Digital Data Security New Zealand Ltd 1998. Copyright © 1990, 1993, 1994 The Regents of the University of California. All rights reserved. This code is derived from software contributed to Berkeley by Mike Olson. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2.
Radio Frequency Interference Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. USA—FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Australia and New Zealand Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. European Union This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility.
Worldwide Customer Support Customer support for this or any other product is available at no charge in any of the following ways: • Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. – www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. – www.apc.com/support/ Global support searching APC Knowledge Base and using e-support.