InfraStruXure™ Manager Installation and Configuration
This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Deze handleiding staat in het Nederlands op de bijgevoegde cd. Este manual está disponible en español en el CD-ROM adjunto. Ce manuel est disponible en français sur le CD-ROM ci-inclus. Questo manuale è disponibile in italiano nel CD-ROM allegato. Instrukcja Obslugi w jêzyku polskim jest dostêpna na CD.
Contents Product Description..................................................1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Receiving inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Please recycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Information .............................................. 16 APC InfraStruXure Manager front panel . . . . . . . . . . . . . . . 16 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 APC InfraStruXure Manager . . . . . . . . . . . . . . . . . . . . . . . 17 RS-485 Pin-out (COM 2) . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Configure a building management system . . . . . . . . . . . . . 18 Life-Support Policy . . . . . . . . . . . . . . . . . .
Product Description Overview Inventory APC ® InfraStruXure™ Manager—A 1U management device. The InfraStruXure Manager coordinates the management functions of other APC devices that provide for the management of InfraStruXure, other APC power distribution systems, and cooling solutions. Rack-mount brackets— Brackets used to install the InfraStruXure Manager in a standard, 19-inch (482 mm) enclosure or rack. Power Cords —NEMA 5-15P to IEC 320 C13 and an IEC 320 C13 to IEC 320 C14 power cord.
Product Description: Overview Please recycle The shipping materials are recyclable. Please save them for later use, or dispose of them appropriately. Disclaimer American Power Conversion is not responsible for damage sustained during reshipment of this product.
Safety Rack-mounting safety The APC InfraStruXure Manager is shipped with rack-mounting brackets. Install the brackets in the appropriate position for your rack, and mount the unit. The unit is 1U high. If the unit is mounted in an enclosure instead of an open rack, the maximum ambient temperature in the enclosure should be no greater than 95° F (35° C). • When you install equipment in the rack, make sure it does not interfere with the air flow required for safe operation for the equipment.
Installation Install the InfraStruXure Manager Attach mounting brackets to the InfraStruXure Manager 1. Attach the left and right mounting brackets to the InfraStruXure Manager, using two flat-head, #2 Phillips screws (provided) for each bracket. See the manufacturer’s documentation for the switch (or hub) for specific installation instructions.
Installation: Install the InfraStruXure Manager Mount the InfraStruXure Manager and switch (or hub) in an enclosure This procedure describes how to install components in an APC NetShelter® enclosure. If you are installing components in a different enclosure, the procedure may vary. Note Leave room above the switch (or hub) to route data cables. To install the InfraStruXure Manager in a NetShelter enclosure: 1.
Installation: Install the InfraStruXure Manager 2. Align the mounting holes on the brackets with the caged nuts you installed in step 1, and insert two mounting screws (provided with the enclosure) to secure the brackets to the enclosure. t The switch (or hub) and the InfraStruXure Manager are not required to be installed in the same rack, as they are in the installation described here.
Communication Connection Network overview The InfraStruXure Manager provides for the management of other networked APC devices. It connects to both your existing network (User LAN) and a private APC network (APC LAN) to manage connected APC devices. Use the APC LAN for APC devices whenever possible. Public network Private network ISX manager User LAN User LAN port APC LAN port Managed device 1 APC switch 1 APC switch 2 Managed device 2 Connect network cables to InfraStruXure devices 1.
Installation: Communication Connection Route network cables to the InfraStruXure Manager switch (or hub) Overhead routing. This section is for InfraStruXure system installations. 1. Ensure that the APC Shielding Partitions and Cable Ladders are installed on the NetShelter enclosures and the InfraStruXure PDUs. 2. Run the Cat-5 network cables (provided) from each APC device to the switch (or hub). a. Start with the device farthest from the switch (or hub), and use the longest supplied CAT-5 cable. b.
Installation: Communication Connection Connect the InfraStruXure Manager and switch (or hub) This section is for InfraStruXure system installations. 1. Connect the InfraStruXure Manager’s APC LAN port to any network port on the hub, using the CAT-5 network jumper cable (provided). .
Installation: Communication Connection Apply power to the InfraStruXure Manager and switch (or hub) After you install the InfraStruXure Manager and switch (or hub) and make all of the communication connections, connect the power cords to a Rack PDU within the enclosure to apply power to the InfraStruXure Manager.
Initial Configuration Configure the InfraStruXure Manager To configure the InfraStruXure Manager for the first time you must connect to the manager and run the APC InfraStruXure Manager Setup Wizard on the client interface. You have two options for connecting to the manager: • Connect from the private network (APC LAN) with a computer connected to the APC switch (or hub).
Initial Configuration: Configure the InfraStruXure Manager W If you click No, you can run the wizard at any time. From the System Management menu, select the Server option and then select Setup Wizard. Note 7. On the License Key page of the wizard, enter the license key to enable the InfraStruXure Manager to manage APC devices on the private network (APC LAN) or discover and manage APC devices on the public network (User LAN). 8.
How to Restore Access to the InfraStruXure Manager Server If the username or password used for local, Administrator access becomes unknown, or RADIUS only is selected in the “Authentication Settings” display and a RADIUS server is unavailable, you can use the following procedure to restore access to the InfraStruXure Manager server. 1. Connect a computer to the hub on the private network. That computer must have the InfraStruXure Manager client installed.
Enable Remote Monitoring APC can monitor your InfraStruXure Manager and the devices it manages, and notify you of events via e-mail, pager, or phone. If you decide to use APC’s Remote Monitoring Service (RMS), follow these steps: 1. From the Event Management menu, select Remote Monitoring Service 2. In the APC Remote Monitoring Service Registration window, Click the RMS Settings... button at the lower-right. 3.
Initial Configuration: Enable Remote Monitoring 4. In the RMS Settings window, fill in all of the required fields on the Contact Information and Company Information tabs, and then click Save. 5. Click OK to return to the APC Remote Monitoring Service Registration window. 6. In the APC Remote Monitoring Service Registration window, select the Enable APC’s Remote Monitoring Service check box, and click Apply. 7. Visit http://rms.apcc.com to complete the RMS configuration.
Product Information APC InfraStruXure Manager front panel USB1 Kbd COM 2 RS-485 COM 1RS-232 HDD Rx/Tx 100 Monitor Reset Pwr Item 16 User LAN APC LAN Function COM 2 RS-485 RS-485 port that allows integration with a Building Management System using the MODBUS® protocol. USB 1 Universal Serial Bus port (USB 1.1). COM 1 RS-232 RS-232 port. HDD Hard disk drive LED. When this LED is amber, the disk is being accessed. Pwr Power LED.
Specifications APC InfraStruXure Manager Electrical Input 100–240 VAC; 50/60 Hz; 0.7 A Physical Dimensions (H × W × D) Unit 1.75 ×17.0 × 6.75 in (4.5 × 43.2 × 17.2 cm) Shipping 8.5 × 22.75 × 13.25 in (21.5 × 57.78 × 33.65 cm) Weight Unit 6.6 lb (3.0 kg) Shipping weight 11.5 lb (5.
Product Information: Specifications RS-485 Pin-out (COM 2) COM 2 RS-485 Pin RS-485 Signal 1 — 2 Do not connect 3 RxD/TxD + 4 Reserved 5 — 6 Reserved 7 Do not connect 8 RxD/TxD – 9 — Shell Chassis GND The COM 2 RS-485 port is not equipped with terminating, ground current limiting, or pull-up resistors. The installer must provide them. Note Configure a building management system To configure the MODBUS®-RTU building management system interface, select Build Management System...
Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: • In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness. • In direct patient care.
Warranty and Service Limited warranty APC warrants the InfraStruXure Manager to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way.
Radio Frequency Interference a Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. USA—FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. – www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. – www.apc.com/support/ Global support searching APC Knowledge Base and using e-support.