Metered Rack PDUs
Metered Rack PDUs provide real-time remote
monitoring of connected loads. User-defined alarms
warn of potential circuit overloads before critical IT
failures occur.
Vertical, 0U 100 – 120 NAM, Japan 15 A 1.4 kW NEMA 5-15P (16) 5-15 3.0 m AP8831
Vertical, 0U 100 – 120 NAM 20 A 1.9 kW NEMA L5-20P (24) 5-20 3.0 m AP8830
Vertical, 0U 100 – 120 Japan 20 A 2.0 kW NEMA L5-20P (24) 5-15 3.0 m AP8830J
Vertical, 0U 100 – 120 Japan 20 A 1.9 kW NEMA L5-20P (10) 5-15 3.0 m AP8833J
Vertical, 0U 100 – 120 NAM, Japan 30 A 2.9 kW NEMA L5-30P (24) 5-20 3.0 m AP8832
Vertical, 0U 100 – 120 Japan 30 A 2.4 kW NEMA L5-30P (24) 5-15 3.0 m AP8832J
Horizontal, 1U 120 NAM, LAM 15 A 1.4 kW NEMA 5-15P (8) 5-15 3.6 m AP7800
Horizontal, 1U 120 NAM, LAM 20 A 1.9 kW NEMA L5-20P (8) 5-20 3.6 m AP7801
Horizontal, 2U 120 NAM, LAM 30 A 2.9 kW NEMA L5-30P (16) 5-20 3.6 m AP7802
Horizontal, 2U 100 Japan 30 A 3.0 kW NEMA L5-30P (16) 5-15 3.6 m AP7802J
Vertical, 0U 230 Worldwide 10/15 A 2.3 kW IEC-320 C14 (16) C13 3.0 m AP7850
Vertical, 0U 100 – 240 Worldwide 16 A 3.3 kW IEC-320 C20* (18) C13 (2) C19 Inlet AP8858
Vertical, 0U 100 – 240 EMEA, APJ, 16 A 3.7 kW IEC-309 16 A (18) C13 (2) C19 3.0 m AP8858EU3
Vertical, 0U 100 – 240 NAM, LAM 20 A 3.3 kW NEMA L6-20P (18) C13 (2) C19 3.0 m AP8858NA3
GCN, APJ
Vertical, 0U 200 – 240 NAM, Japan 30 A 5.0 kW NEMA L6-30P (36)C13 (6) C19 3.0 m AP8841
LAM
Vertical, 0U 208 NAM 30 A 5.8 kW NEMA L14-30P (16) 5-20 (12) 3.0 m AP8870
(2) C19
Vertical, 0U 220 – 240 LAM, EMEA, 32 A 7.4 kW IEC-309 32 A (36)C13 (6) C19 3.0 m AP8853
GCN, APJ
Horizontal, 1U 100 – 240 Worldwide 10/15 A 2.5 kW IEC-320 C14* (8) C13 Inlet AP7820
Horizontal, 1U 100 – 240 Worldwide 16 A 3.3 kW IEC-320 C20* (8) C13 Inlet AP7821
Horizontal, 2U 200 – 240 NAM 30 A 5.0 kW NEMA L6-30P (12) C13 (4) C19 3.6 m AP7811
Horizontal, 2U 230 LAM, EMEA, 32A 7.4 kW IEC-309 32 A (12) C13 (4) C19 3.6 m AP7822
GCN, APJ
* See page 20/21 for inlet power cord options
100 – 120 V Input200 – 240 V Input
Mounting
U-space
Nominal
Power
Nominal
Voltage
Input Plug
Type
Voltage Input
Circuit
Output
Receptacles
Cord
Length
APC SKURegion
Rack PDU local display
AP8000 seriesAP7000 series
Load indicator LEDs User-interactive
display for local access
CAN In/Out ports for
network port sharing
Local USB port for flash firmware
updates and downloading data/event
logs (not to be used as serial port)
Environmental monitoring port for
external temperature/humidity probe
Serial connection: local configuration
and out-of-band management
Local two-digit LED
current monitoring display
Network management: access, configure,
and receive warnings from remote
locations via Web, SNMP, and Telnet