Specifications
WWW.APART-AUDIO.COM
8
8) Signalledchannel2:thisledlightsupgreenwhenasufcientlystrongsignalispresent
on the left channel, after passing the input level control. At startup, the led will light up red
during a few seconds, this is perfectly normal. When it lights up red during use, the power
transformerorpoweramplierisoverheatedorinprotectmodeandisshutdown.Turnoffthe
power. The amplier will not turn on automatically after most error conditions. In some
cases, the user MUST turn off power and remove the overload and then power on
again ! More details can be found in the table below.
9) APCactivityledrightchannel:thisledlightsupwhentheAPCcircuitryisactive.TheAPC
circuitry reduces the gain at the inputs to guarantee the full dynamic range of the power
ampliercircuits.
10)Clipledchannel2:thisledlightsupwhenevertheamplierclips.Thisisawarningsign:you
are pushing things a little too far or you are overloading the amp. Reduce the input level by a
few dB so that this led never lights up anymore ! Don’t ignore this !
11)Templedleftchannel:thisledlightsupwhentheamplierisabouttooverheat.Outputpower
willautomaticallybelimitedbytheAPCcircuitrytoavoidfurtheroverheating.Thispartofthe
protection circuit resets itself automatically when temperature has normalized. When both
signalled(2)andtempled(5)arered,thepowertransformer’sthermalprotectionisactive
andtheamplierisshutdown.Turnoffthepowerandletitcooldown. The amplier will not
turn on automatically after it has cooled down, the user MUST turn off power, wait for
cooling down and then power on again ! More details can be found in the table below.
12)Volumepotmeterchannel2:usethispotmetertopresetthevolume.Inbridgemode,this
potmeter has no function.