Operator`s manual

10
Operation
Out Of Level Warning. The Out of Level (OOL)
Warning is used with certain lasers that have the
ability to indicate they are out of level by changing
their rotation speed.
The factory default setting is Laser Out of Level Warning off.
To activate the laser OOL Warning, turn the receiver on. Press and hold
the power switch and then press and release the brightness switch.
A flashing "X" pattern indicates if the OOL Warning
is activated. If
the center green LED is not lit, the OOL Warning is off. Pressing the
power /
brightness switch combination again while the "X" pattern is
activated will turn the warning on. The center green LED will come on
to confirm the OOL Warning is on. Pressing the
power /
brightness
switch combination again while the "X" pattern is activated will toggle
between on and off.
When the warning is turned on and the laser drops to 300 RPM, a
flashing "X" will appear on the display to let the machine operator know
the laser is out of level.
Laser Out Of Level ONLaser Out Of Level OFF
+