PROBLEM 5: AIR PRESSURE LEVEL IS SIGNIFICANTLY LOW NO MATTER
HOW HIGH THE AIRFLOW LEVEL IS CALIBRATED
Case 1: Check the mains voltage (AC power source). If the voltage level
falls significantly low, about 15-20% lower than the standard, there will also
be a noticeable drop in the air pressure level.
SOLUTION: Please refer to your local power service provider.
Case 2: The microcontroller might have detected the operating frequency
incorrectly. The airflow level is noticeably weaker.
SOLUTION: Try to press the “Reset” button on the panel and let the
device re-detect the proper operating frequency. Note that resetting the
device will also reset all previously defined configurations.
PROBLEM 6: THE SOLDERING IRON DISPLAYS “Pen” or “Err”
Case 1 “Pen”: Soldering Iron is not properly connected to the unit, unplug
Soldering Iron and reattach to connector. Soldering Iron sensors may has
been damage and needs to be replaced.
Case 2 “Err”: Soldering Iron cannot reach the desire set temperature,
sensor could have been shorted due to wrong connection or heating
element has reached the end of it life.
SOLUTIONS: Check internal pen connection, replace heating element.
PROBLEM 7: DISPLAY & OTHER DEVICE OPERATION ISSUES
SOLUTION: Try to press the “Reset” button on the device. Note that
resetting the device will also reset all previously defined configurations.
OTHER PROBLEMS NOT MENTIONED:
Contact the vendor.
BASIC TROUBLESHOOTING GUIDE