Instruction manual

16
DIGITAL CALIBRATION
6. Adjust the temperature compensation using the UP and
DOWN buttons of the Soldering iron
adjustment buttons.
7. A zero “0” on the first digit signifies addition to the current
temperature and a minus “-” on the first digit will subtract
the displayed value from the current settings.
8.
Confirm the change by pressing the air pressure down
button.
Initial display
when in cali-
bration mode
Increase tem-
perature by 38
degrees
Decrease tem-
perature by 30
degrees
Solder Iron Digital Temperature Calibration Example
The external temperature sensor displays 248 to 252 degrees.
The set temperature and displayed actual temperature of the
soldering iron is 300 degrees.
300 — 248 = 52. An additional adjustment of 52 degrees is
required.
Enter calibration mode
We increase from “0000” to “0052”.
Exit calibration mode.
The external temperature sensor would now display 298 to
302 degrees.
9
IMPORTAN
T REMINDERS:
1. Make sure the equipment is placed on a flat stable surface
and all the heat-generating components placed on their re-
spective holders or stands.
2. Ensure all function switches are OFF prior to reworking.
3. Ensure all terminal connections are properly secured.
IMPORTANT: Please refer to the CONTROL PANEL GUIDE
page for buttons and display panel directory.
OPERATING GUIDELINES
A. INITIAL PROCEDURES
1. Plug the device to the main power source using the power cord
provided in the package.
2. With all function switches deactivated and all terminal connections
properly secured, switch ON the device by activating the main power
switch (“8” from the control panel).
3. The display panels, 11 and 12 will temporarily show the product name
in a scrolling manner and then display “OFF” on all rows once the
scroll is finished (see below illustration). The system will remain at this
state until the user activates a function.
B. HOT AIR GUN
1. Follow the initial procedures above, “A. INITIAL PROCEDURES
”.
2. Activate “Hot Air Gun” switch (“14” from the control panel).
3. The system will immediately start to blow air at an airflow rate of 50
while rapidly and safely increasing the air temperature to 100°C
(default system operating parameters). These values will be reflected
from the Hot Air Gun Air Temperature and Air Pressure display
panels, “13” and “12” from the control panel, respectively. The metal
ball inside the air gauge (“1” from the control panel) will also settle
somewhere in the middle of the visible area indicating that the system
is blowing air at an average or normal rate.