CARE and MAINTENANCE
Changingnozzle:
● Unscrewthesecuringlockandpulloutthe heaterexternalhousingtogether
with the securing lock, Nozzle can now be changed. Resecure nozzle by
tightenthesecuringlockonitsreceptacle.
ChangingFilterpadandFilterSpring:
● Unlockthefilterdockbytogglingthefilterdocklockingmechanism.Thefilter
dock would push out to allow easy extraction of the filter barrel assembly
whichhousesthefilterpad,filterspringandfilterbarrelcap.
After extracting the Filter Barrel
Assemblywecannowtakeoutthe
filter spring or the filter pads for
cleaningorreplacement.
ReassembleFilterBarrel assembly
attach spring filter to the filter
barrel cap and place back to the
desolderinggunbody.
PushtheFilter dockbackinplace
a “click” sound would signify that
thefilterdockisproperlysecured.
Filterdocklocking
mechanism
FilterDock
FilterBarrelAssembly
FilterDock
7
SAFETY PRECAUTIONS
CAUTION:Improperusagecancauseseriousinjurytopersonnel
and/ordamagetoequipment.Foryourownsafety,pleaseobserve
theff.precautions.
● Check each component after opening the package to make sure
everythingisingoodcondition.Ifthereareanysuspecteddamage,
donotusetheitemandreporttheissuetoyourvendor.
● Turn OFF the main power switch and unplug the device when
movingthedevicefromonelocationtoanother.
● Do not strike or subject the main unit to physical shock. Use
carefullytoavoidinjuryanddamagetoanypart.
● Handlewithcare.
Neverdroporsharplyjolttheunit.
Containsdelicatepartsthatmaybreakiftheunitisdropped.
● Make sure the equipment is always grounded. Always connect
powertoagroundedreceptacle.
● Temperaturemayreachashighas480°CwhenswitchedON.
Do not use the device near flammable gases, paper and other
flammablematerials.
Donottouchheatedparts,whichcancausesevereburns.
Donottouchmetallicpartsnearthetip.
● Disconnect the plugfromthepowersourceifthe unit willnot be
usedforalongperiod.
Turnoffpowerduringbreaks,ifpossible.
● Useonlygenuinereplacementparts.
Turnoffpowerandlettheunitcoolbeforereplacingparts.
● Theunitmayproduceasmallamountofsmokeandunusualodor
during initial usage. This is normal and should not yield any
negativeresultwhenreworking.
● Solderingprocessproducessmoke—useonwellventilatedplace.
● Do not alter the unit, specifically the internal circuitry, in any
manner.