Instruction manual
28
BASIC TROUBLESHOOTING GUIDE
PROBLEM6:SOLDERINGIRONTEMPERATUREDISPLAYPANEL
SHOWS“PLUG”CHARACTERS
Case1: The system shows “PLUG” from the soldering iron temperature
displaypanel.
SOLUTION1:Check if the soldering iron connection assembly i s properly
con nectedandsecuredto thereceptacleonthecontrolpanel.
SOLUTION2:Make sure the soldering ir on tip is properly inserted and
secur edinsidethehandle.Loose contactsbetweenthetipandhandlecanalso
causethiserrormessage.
SOLUTION3:See“Soldering Iron Error Messages”onpage21forfurther
details.
PROBLEM 7:AIRPRESSURELEVELISSIGNIFICANTLY LOWNO
MATTERHOWHIGHTHEAIRFLOWLEVELISCALIBRATED
Case 1: Checkthemainsvoltage(ACpowersource).Ifthevoltagelevelfalls
significan tly low, about 1520% lower than the standard,there will also bea
noticeabledropintheairpressurelevel.
SOLUTION:
Pleaserefertoyourlocalpowerservice provider.
Case 2: The micr ocon troller m ight have detected the operating frequency
incorrectly.Theuserwillnoticethatairflowlevel isweakerwithreferen ceto
theairflowgaugecomparedwiththedisplayedvalue.
SOLUTION:
Turnoff theunitandonagain toletthedeviceredetect theproperoperating
frequency
5
2703A+Main
HotAirGunand
HotAirGunHolder
DesolderingGun
andHolder
AirNozzles
(1124,1130,1197,1313,1919,1010)
SolderingIronwith
SmokeAbsorber
PowerCord
30150J
HeatResistantPad
939VacuumSuctionPen
G001ICPopper
3017JFilter
Pads(6pcs.)
201242Nozzle
cleaningpin
20125Filter
Spring
Desolderingtips
2630BSolderingIronHolder
withSolderWireStand
LF2BTipwith
HeaterCartridge
SuctionVacuumCap
FilterVacuumCap
PACCKAGE INCLUSIONS
2703 A+