Instruction manual
18
AUTO SLEEP FUNCTIONS
F.AutoSleepMode(HotAirGun)
The device has a builtin autosleep mode featuresuch that if the
HotAirGunsitsonitshandleandremainedidleafteracertainperiodthe
prefixofthedisplayforHotAirGunairtemperaturewillalsochangefrom
“C” to “d”) , the device will switch to sleep mode. This mechanism is
triggeredbyacountdowntimer.Whenthetimerhaselapsed,thesystem
will blow air (at room temperature) at maximum rate in order to bring
downthetemperature.Duringthistime,theHotAirGunairleveldisplay
willchangeto“cool”.Oncethetemperaturedropstoapproximately90°
C,theHotAirGunwillautomaticallystopandshowfourdashes“ “
indicatingthatthesystemisnowinsleepmode.Toreactivatethehotair
gunsimplypresspickupthehotairgunfromitsdock.
ChangingSLEEPM odeTimer(HOTAIRGUN)
Bydefault,thesystemhas15minutecountdowntimebeforethehot
air gun goes to sleep mode. This can be altered by the following
procedure.
1. Whilethe hotairgunis on standbymode(“0FF”isdisplayedon
the panels “18” and “16”), Press and hold the UP button of the
HOTAIRGUNAIRFLOWadjustmentbutton(“3”controlpanel).
2. Wait until “015d” is displayed on the Hot Air Gun Temperature
displaypanel,“18”.
3. Releasethebuttonwhen“005d”appears.
4. AdjustthetimeusingtheUPandDOWNbuttonsoftheHOTAIR
GUNTEMPERATUREadjustmentbuttons(“2”controlpanel).
5. Confirmthe changeby pressingandholdingthe DOWN buttonof
the HOT AIR GUN AIRFLOW adjustment button. (“3” from control
panelguide)
6. Thesystemwillswitchbacktodisplaying“OFF”indicatingthenew
sleeptimerissavedintothesystem.
15
OPERATING GUIDELINES
4. Activatethe“DESOLDERGUN”Activationswitch(“12”fromcontrol
panel).Thiswill automaticallystart to increasethetemperatureof
thedesolderinggunto350°C(default).
5. Adjust the desoldering gun temp. using the DESOLDER
TEMPERATUREADJUSTMENTbuttons(“5”fromthecontrolpanel).
6. Allow the desoldering gun's tip and its barrel to heat up. Tip
temperaturecanbereachedwithin56minutesanditsbarrelwould
obtainoptimumtemperature59minutesafterthetiptemperature
hasbeenreached.Ifuponinitialusesoldergetsstuckattheendof
the barrel, clean the barrel and wait a few more minutes for the
barreltoheatup.
7. Check the tip temperature with an external temperature sensor,
adjust temperature settings higher or lower for the right
temperature.Orrecalibrateatthedesiredtemperaturelevel
8. Ensure that all the solder is melted before triggering the pump.
(Partiallymeltedsolderwillstillbesuckeduphoweveritwouldclog
thebarrel).
9. Upon pressing the pump trigger hold the trigger for 1 to 2
secondslonger,aslargerlumpsofsoldermayneedalongersuction
timetoclearthebarrelandgointothefilter.
10. Cleanthefilteranddampenthespongefrequentlyduringandafter
usagetoallowbettersuctionpower.
11. When thetaskis finished, deactivate theDESOLDERGUN function
switch.Allowthedesolderingguntocooldownbeforehandlingfor
storage.
Notes:
● Pleasefollowtheproceduresandtipspresentedaboveformore
efficientusageofthedesolderinggun.
● Industry recommended tip temperature for soldering is 600 to
610F(315to320C)forstandardsoldersand650to700F(340to
370)forunleadedsolders