14
OPERATING GUIDELINES
D.SOLDERINGIRON
1. Connect the Soldering Iron connection assembly to the 6pin
receptacle located at the front of the control panel (“9” from the
CONTROLPANELGUIDE).
2. Followtheinitialprocedures(“A.INITIALPROCEDURES”).
3. Connect the vacuum tube to the Smoke Absorber Terminal or
Vacuum Cap (“7” from the control panel). If smoke absorber
functionistobeused.
4. Activate the “SOLDER IRON” Activation switch (“14” from control
panel).Thiswill automaticallystartto increasethetemperatureof
thesolderingironto350°C(default).
5. AdjustthesolderingirontemperatureusingtheSOLDER/DESOLDER
TEMPERATUREADJUSTMENTbuttons(“4”fromthecontrolpanel).
6. If smoke absorber function is to be used. Activate the “SMOKE
ABSORBER”Activationswitch(“15”fromthecontrolpanel).
7. Start using the soldering iron as soon as desired temperature is
reached.
8. Whenthetaskisfinished,deactivatetheSMOKEABSORBERswitch.
9. DeactivatetheSOLDERIRONactivationswitch.
10. Allow sufficient time for the soldering iron to cool down before
keepinginasafestorage.
D.DESOLDERINGGUN
1. Connect the Desoldering gun connection assembly to the 6pin
receptacle located at the front of the control panel (“8” from the
CONTROLPANELGUIDE).
2. Followtheinitialprocedures(“A.INITIALPROCEDURES”).
3. Connect the vacuum tube to the Smoke Absorber Terminal or
VacuumCap(“7”fromthecontrolpanel).
19
NOTES:
● Thesleepmodetimerisconfigurablebetween1and60minutes.
● Asleepmodetimervalueof“0”disablesthesleepfunction.
● SleepmodesettingsforHotAirgunissavedintothememoryand
shallremainineffectuntilitisresetornewdataisentered.
G.AutoSleepMode(SolderingIronandDesolderingGun)
The device has a builtin autosleep feature to conserve power
enhance the heaterlife. The sleep timer can be configured to power
downthesolderingironordesolderinggunafteradefinedtime.When
insleepmodefourdashes“ “willbeshownindicatingthatitis
nowinsleepmode.Toreactivatethesolderingironordesolderinggun
simply push the its function button or its temperature adjustment
button.
ChangingSLEEPTimer(SolderingIron)
By default, the system’s sleep duration is 0 indicating the sleep
timerisdisabled.Toactivatethesleepfunctionfollowtheprocedures.
1. TurnofftheSolderingIronFunctionswitch(“14”fromthecontrol
panel).EnsurethattheDesolderingGunFunctionswitchisinthe
offposition(“12”fromthecontrolpanel).
2. Press and hold the DOWN button of the Desoldering Gun
TemperatureAdjustmentbutton(“5”fromthecontrolpanel).
3. The Soldering IronTemperatureDisplay (“14” fromthecontrol
panel).Willswitchto“000t”indicatingitisnowinthesoldering
ironsleeptimeradjustmentmode.ReleasetheDOWN buttonof
theDesolderingGunTemperatureAdjustmentbutton
4. UsetheSolderingIronTemperatureAdjustmentbuttons(“4”from
the control panel) to increase or decrease the sleep duration.
Timer is adjustable from1 to 60 minutes,a valueof0 indicates
thatthesleeptimerfunctionisturnedoff.
5. Confirmthechangebypressingandholdingthe“DOWN”button
ofthe DesolderingGunTemperatureAdjustmentbutton(“5”from
thecontrolpanel).
AUTO SLEEP FUNCTIONS