BASIC TROUBLESHOOTING GUIDE
PROBLEM1:THEUNITHASNOPOWER
1. CheckiftheunitisswitchedON.
2. Checkthefuse.Replacewiththesametypeiffuseisblown.
3. Checkthepowercordandmakesuretherearenodisconnections.
4. Verifythattheunitisproperlyconnectedtothepowersource.
PROBLEM2:TEMPERATUREDISPLAYISALWAYSABOVE500
o
C
Description: Constant display of above500
o
Ctemperature fromthe
panelthendisplaysablinking“OFF”onthepanelafterafewminutes.
SOLUTION:
Thethermalsensormaybebrokenandneedstobereplaced.
PROBLEM3:ACTUALAIRTEMPERATUREISNOTINCREASING
Description: Actual temperature reading is not increasing or
decreasingbasedondesiredlevel.Thepanelwillthendisplayablinking
“OFF”onpanel.
SOLUTION:
Theheatingelementmaybebrokenandneedstobereplaced.
PROBLEM 4: BANNER OR PRODUCT NAME IS ALWAYS
SCROLLINGTHEUNITISNOTUSABLE
Description: Theproductnameisalwaysjustscrollingfromthedigital
panel,renderingthedeviceunusable.
SOLUTION:
Try to press RESET from the control panel. Note that resetting the
devicewillalsoresetallpreviouslydefinedconfigurations.
PROBLEM5:THEUNITISVIBRATINGTOOMUCH
SOLUTION: Check if the 4 screws that hold the pump in place are
properlyandtightlyconnected.Unplugthesystemfromthemainpower
sourcebeforeopeningthecasetocheckinsidethestation.
7
FUNCTION and FEATURES
MicroprocessorcontrolledESDsafeequipment.
3in1repairingsystemcombiningHotAirGun,SolderingIron,and
DesolderingGuninonesophisticatedpackage.
Digital control and display of hot air temperature, soldering iron
temperature, desoldering gun temperature and air pressure with
touchtypepanelcontrolsforprecisionandeaseofuse.
T he desoldering gun is equipped with air cylinder type vacuum
pump forstrongersuctionandzerocrossingcircuit thatprevents
electricalsurges.
Integrated smoke absorber functionality with filter pad to
efficientlyabsorbandfilterharmfulfumes.
Uniquely designed compound tip that integrates the ceramic
heatingelementandsensorinjustonecomponent.Replacingtips
isaseasyasslippingitin/outofthecompatible24Vsolderingiron.
Userconfigurable1to20minuteidletoautostandbymode(with
5 minutes as default) for additional device protection and power
saving.
Builtin autocooling process that protects the system and its
componentsfromexcessiveheat,prolongingusagelife.
Builtinautosleepmodeforsol deringironanddesol deringgun.
Compatibilitywithairnozzl esofvarioustypes.
Compatibilitywithdifferentkindofsolderingtips.