Instruction manual

24
BASIC TROUBLESHOOTING GUIDE
PROBLEM 8: SOLDERING / DESOLDERING TEMPERATURE
DISPLAYPANELSHOWSUNRECOGNIZABLECHARACTERS
Case1: The system produces five (5) high beep sounds then shows
something like “uuu” from the soldering / desoldering temperature
displaypanel.
SOLUTION1: Check if the soldering iron or the desoldering gun
connectionassemblyisconnectedtothe6pinreceptacleofthecontrol
panel.Doublecheckthepinconnectionsifpossible.
SOLUTION2: Makesurethesolderingi rontipisproperlyinserted
and secured inside the handle. Lose contacts between the tip and
handlecancausethiserrormess age.
Case2: The system produces five (5) high beep sounds then shows
something like “ttt” from the soldering / desoldering temperature
displaypanel.
Case4: TheVacuumcapisconnectedbutairflowlevelisstilllow.
SOLUTION:
Checkthefil terpadinsidethevacuumcapfordirtthatcanblocktheair
passage.Cleanorreplaceifnecessary.
ADDITIONALSOLUTION: Check for any tangles in the tube of the
hotairgunthatcancausetheairblockage.
5
2702MainStation
HotAirGunand
HotAirGunHolder
DesolderingGun
andHolder
AirNozzles
(1124,1130,1197,1313,1919,1010)
SolderingIronwith
SmokeA bsorber
PowerCord
30150J
HeatResistantPad
939VacuumSuctionPen
G001ICPopper
3017JFilter
Pads6pcs.
201242Nozzle
cleaningpin
20125Filter
Spring
Desolderingtips
2630BSolderingIronHolder
withSolderWireStand
LF2BTipwith
HeaterCartridge
SuctionV acuumCap
FilterVacuumCap
PACCKAGE INCLUSIONS