Instruction manual
12
OPERATING GUIDELINES
A. INITIAL PROCEDURES
1. Plug the device to the main power source using the power cord
providedinthepackage.
2. With all function switches deactivated and all terminal connections
properly secured, switch ON the device by activating the main
powerswitch(“9”fromthecontrolpanel).
B. HOT AIR GUN
1. Followtheinitialproceduresabove,“A.INITIALPROCEDURES”.
2. Activate“HotAirGun”switch(“14”fromthecontrolpanel).
3. Thesystemwillimmediatelystartto blowairatan airflow rateof
51whilerapidlyandsafelyincreasingtheairtemperatureto100°C
(default system operating parameters). These values will be
reflectedfromthe Hot Air GunAir Temperature and Air Pressure
display panels, “11” and“12” from the control panel,respectively.
Themetalballinsidetheairgauge(“1”fromthecontrolpanel)will
also settle somewhere in the middl e of the visible area indicating
that the system is blowing air at an average or normal rate. (See
illustrationsonthenextpage.)
3. The display panels, 11 and 12 will temporarily show the product
name in a scrolling manner and then display “OFF” on both rows
once the scroll is finished(see below illustration). The system will
remainatthisstateuntiltheuseractivatesafunction.
IMPORTANT:InitialcontrolpanelsettingincludestheBLOWER/VACUUM
ACTIVATIONswitch(“10”fromcontrolpanel)setto“Blow
17
OPERATING GUIDELINES
ADDITIONALNOTES:
1. ThealternativetofirststepaboveistopresstheRESETbuttonthenholdt heUP
buttonoftheAIRPRESSUREAdjustmentbuttonsuntil“L05”isdisplayed.Note
thatpressingRESETremovesuserdefinedconfigurations.
2. Thecount downtimerisconfigurablebetween 1 and 20 minutes.
E. Auto-Stand-By Mode (Hot Air Gun)
ThedevicehasabuiltintimersuchthatiftheHotAirGunsitson
its handle and remainidle for a certain period, the device will switch
indefinitely to standby mode (provided the power del ivered to the
systemremain uninterrupted). Once the countdown time has elapsed,
thesystemwillblowair(atroomtemperature)ata maximumratein
ordertobringdownthetemperature.Duringthistime,theprefixofthe
display for Hot Air Gun ai r temperature will change from “A” to “d”.
Oncethetemperaturedropstoapproximately90°C,theHotAirGunwill
automatically stop and show an al ldash display indicating that the
systemisnowonstandby.
The device will automatically switch back into operation with the
last userdefined parameters, i.e., hot air gun temperature, airflow
level,etc.,whentheHotAirGunis liftedagainfromthehandle.
By default, the system has a5minute countdown time. This can
bealteredbythefollowingprocedures.
1.Uponsystemstartup,whiletheproductnameisscrollingfromthe
display panel, hold the UP button of the AIR PRESSURE
Adjustmentbuttonsandwaituntil“L05”isdisplayed.
2.AdjustthetimeusingtheUPandDOWNbuttonsoftheHOTAIR
GUNTEMPERATUREAdjustmentbuttons.
3.Confirm the change by pressing the DOWN button of the AIR
PRESSUREAdjustmentbuttons.
4.Thesystemwillautomaticallyswitchbackintooperation anduse
thedefinedcountdownparameter.