Instruction manual
10
CONTROL PANEL GUIDE
LEGEND:
1—AirflowGauge
2—HotAirGunTemperatureAdjustmentButtons
3—HotAirGunAirflowAdjustmentButtons
4—SolderingIron/DesolderingGunTempControlButtons
5—CalibrationUtilityTerminal
6—HotAirGunOutputTerminal
7—SmokeAbsorberTerminalorVacuumCap
8—SolderingIron/DesolderingGun6PinReceptacle
9—MainPowerSwitch
10—Blower/VacuumActivationSwitch
11—HotAirGunTemperatureDisplay
12—HotAirGunAirPressureDisplay
13—SolderingIron/DesolderingGunTemperatureDisplay
14—HotAirGunActivationSwitch
15—ResetButton
16—SmokeAbsorberSwitc h
17—SolderingIron/DesolderingGunActivationSwitch
19
ADDITIONAL NOTES on AUTO-SLEEP MODE
1. Thedefault timebeforethesolderingironorthe desolderinggun
goes to sleep mode is 30 minutes. This is also fixed and non
configurable.
2. Once the system determines that the time has elapsed, it will
gradually decrease the temperature of the soldering iron or the
desolderinggunthenshowthefollowingfromthedisplaypanelof
theSOLDER/DESOLDERTEMPERATURE.
ADDITIONAL NOTES:
SOLDERING IRON and DESOLDERING GUN
1. Because of the difference in the heating element and size of the
solderingi rontipanddesolderinggun,thesolderingironwillheat
up faster than the desoldering gun. This is normal and does not
haveanyimpactonthesystem’sperformance.
2. Therewillbeaslightdropintemperaturedisplayoncethetrigger
ofthedesolderinggunisused.Thisisduetorapidintakeofairin
whichtemperatureissignificantly coolerthanthedesoldering gun
tip. When the system detects this, it will automatically adjust the
temperaturetocompensateforthetemperaturedifference.
3. To deactivate the autosleep mode, deactivate the SOLDER IRON
then activate it again, this time, without holding the Soldering /
Desoldering Temperature Adjustment buttons. Note that pressing
this will also remove the previous temperature value. Re
adjustmentmaybenecessary.
OPERATING GUIDELINES