User Manual
16 
DIGITAL CALIBRATION 
6.  Adjust the temperature compensation using the UP and 
DOWN buttons of the Soldering iron
 adjustment buttons. 
7.  A zero “0” on the first digit signifies addition to the current 
temperature and a minus “-” on the first digit will subtract 
the displayed value from the current settings. 
8. 
Confirm the change by pressing the air pressure down 
button.
Initial display 
when in cali-
bration mode 
Increase tem-
perature by 38 
degrees 
Decrease tem-
perature by 30 
degrees 
Solder Iron Digital Temperature Calibration Example
●  The external temperature sensor displays 248 to 252 degrees. 
●  The set temperature and displayed actual temperature of the 
soldering iron is 300 degrees. 
●  300 — 248 = 52. An additional adjustment of 52 degrees is 
required. 
●  Enter calibration mode 
●  We increase from “0000” to “0052”. 
●  Exit calibration mode. 
●  The external temperature sensor would now display 298 to 
302 degrees. 
 9 
IMPORTAN
T REMINDERS:
1. Make sure the equipment is placed on a flat stable surface 
and all the heat-generating components placed on their re-
spective holders or stands. 
2.  Ensure all function switches are OFF prior to reworking. 
3.  Ensure all terminal connections are properly secured. 
IMPORTANT:  Please refer to the CONTROL PANEL GUIDE 
page for buttons and display panel directory.
OPERATING GUIDELINES 
A. INITIAL PROCEDURES 
1.  Plug the device to the main power source using the power cord 
provided in the package. 
2.  With all function switches deactivated and all terminal connections 
properly secured, switch ON the device by activating the main power 
switch (“8” from the control panel). 
3.  The display panels, 11 and 12 will temporarily show the product name 
in a scrolling manner and then display “OFF” on all rows once the 
scroll is finished (see below illustration). The system will remain at this 
state until the user activates a function. 
B. HOT AIR GUN 
1.  Follow the initial procedures above, “A. INITIAL PROCEDURES
”. 
2.  Activate “Hot Air Gun” switch (“14” from the control panel). 
3. The system will immediately start to blow air at an airflow rate of 50 
while rapidly and safely increasing the air temperature to 100°C 
(default system operating parameters). These values will be reflected 
from the Hot Air Gun Air Temperature and Air Pressure display 
panels, “13” and “12” from the control panel, respectively. The metal 
ball inside the air gauge (“1” from the control panel) will also settle 
somewhere in the middle of the visible area indicating that the system 
is blowing air at an average or normal rate. 