Specifications
- DELAY-TIME
DD
W
DD n.n n.n = 0.0 - 9.9 sec ( DEFAULT = 2.0
sec )
Delay before shifting to next channel.
nn = FF HOLD
DD R DDn.n or DDFF
- FREE SCAN
SP W
SPnn n.n = 0.0 - 9.9 sec (decimal can be
omitted)
n.n = 0.0 FREE-SCAN OFF ( DEFAULT )
= 0.1 - 9.9 sec
SP R SPn.n
- SELECT S-METER
SF W n = 0 DIGTAL METER dBuV ( DEFAULT )
n = 1 DIGTAL METER dBm
R SFn
- DUPLEX ON/OFF
OFnnx W OFnnx nn = 00 - 47 ( 00 = OFF )
x = + or -
OF R OF xnn
- DUPLEX FREQ
OLmm nnnn W OLmm nnnnnnnn00 mm = 01 - 19
SETTING
nnnn n = FREQ-DATA ( up to 1000 MHz, 100
Hz step )
OLmm R OLmm nnnnnnnnnn
OL OLmm nnnnnnnnnn
- INTERVAL TIME
ABnn ABnn nn = 02 - F0
OF AUTO ATT/AMP
nn = 02 APPROX 100 ms
nn = 03 150
nn = 08 350
nn = 0B 500 ( DEFAULT )
nn = 10 700
nn = 30 2000
nn = F0
AB ABnn
- S-METER LEVEL
LU R LU S-METER LEVEL ( dBuV )
( dBuV )
LU nnn -nn ~ nnn
- S-METER LEVEL
LB R LB S-METER LEVEL ( dBm )
( dBm )
LB nnn -nnn ~ nnn
- S-METER GAIN
KKnn W KKnn nn = 00 - 99 ( 1.00 - 1.99 )
(constant)
KK R KK nn