Specifications
frequency in Hz.
RF R Active VFO's Frequency. RFnnnnnnnnnn ( Hz )
- FREQ STEP
STnnnnnn W
Frequency STEP in Hz. Not valid for Search.
(AUTO MODE will be set to off)
STnn.nn Frequency STEP in KHz.
STnn Frequency STEP in KHz.
ST R Frequency STEP in Hz. STnnnnnn ( Hz )
- RECEPTION MODE
MDn W n = 0 NFM ( BW = 15 K )
n = 1 WFM ( BW = 300 K )
n = 2 AM ( BW = 6 K )
n = 3 SFM ( BW = 6 K )
n = 4 WAM ( BW = 15 K )
MD R MDn
- AGC
AC n W n = 0 AGC-OFF
n = 1 AGC-FAST
n = 2 AGC-SLOW
n = 3 AGC-MIDDLE
AC R ACn
- RF-ATTENUATOR
ATn W n = 0 00 dB
n = 1 10 dB
n = 2 20 dB
n = 3 AUTO (Depending on the signal level,
RF-AMP will automatically change to on or off)
AT R ATn ( n = 3 AUTO ATT/AMP )
- RF-AMP
AMn W n = 0 RF-AMP OFF
n = 1 RF-AMP ON
n = 2 AUTO (Depending on the signal level, ATT
will automatically change to on or off)
R Amn ( n = 3 AUTO ATT/AMP )
- NOISE-SQUELCH
RQnnn W RQnnn nnn = 000 - 255
THRESHOLD
This command can be applied to VFO, MEMORY
and SEARCH DATA
When the optional Remote Control Panel is
connected, the AF-volume must be turned to
minimum for the command to function.
RQ R RQ nnn