Specifications

69
IF-OUT SIGNAL LEVEL ACCURACY:
The on screen SIGNAL level values (dBuV or dBm), as well as the SIGNAL level values
streamed through the RS232C port to the PC, are only approximate.
For better accuracy in signal level values, connect a spectrum analyzer such as SDU5600 to
the receiver’s IF OUT port.
Make sure that both the AR-ONE and SDU5600 (or similar) are set to communicate at the
same RS232C port speed.
The signal level value accuracy through the AR-ONE’s “IF OUT” is as follows:
RF Input = -47dBm
BAND RX Freq.(MHz)
10.7M_out Range
1 0 - 1.7 0.9 -65 -50
2 1.7 - 25 11.0 -65 -50
3 25 - 60 42.0 -52 -35
4 60 - 108 84.0 -52 -33
5 108 - 142 125.0 -52 -33
6 142 - 174 158.0 -52 -33
7 174 - 224 199.0 -52 -33
8 224 - 335 279.0 -52 -33
9 335 - 480 407.0 -52 -33
10 480 - 690 585.0 -52 -33
11 690 - 1030 865.0 -52 -33
12 1030 - 1696
1363.0 -52 -33
13 1696 - 3300
2501.0 -52 -33
If you wish to send these signal level values to the PC, it is advised to connect your PC to
the spectrum display’s RS232C port, not to the RS232C port of AR-ONE.
(Specifications are subject to change without notice or obligation.)