Specifications

59
AUTO SIGNAL LEVEL
LC
LCn
n:0 Auto Signal Level off
n:1 Auto Signal Level on
While n is set to 1, and the squelch opens, the signal level and frequency
information is sent to the PC
To read: LC <CR>
LCn
SQm LMnnn RFnnnnnnnnnn
Response:
m: 0 Noise squelch mode
m: 1 Level squelch mode
nnn: signal level from 000 to 999
nnnnnnnnnn: frequency
AUTO BACKLIT
Lan (n: 0 - 2)
n: 0 LAMP OFF
n: 1 LAMP ON (Default)
LA
n: 2 LAMP AUTO
(Will go off in 5 seconds after the squelch is closed)
To read: LA<CR>
Response: LAn
BACKLIT ON/OFF
BLn (n: 0 or 1) Available when LA is set to 2 (Auto).
n: 0 BACKLIT OFF
BL
n: 1 BACKLIT ON (Default)
To read: BL<CR>
Response: BLn