Specifications
43
is set OFF.
The default setting for Manual AGC is 255, maximum gain control value. The value can be
adjusted according to the receiving condition.
To access the configuration menu, push the FUNC key and then push the 7 key.
Push the down arrow key to move the cursor to the “MANU AGC” selection point.
Use the main tuning dial, the right arrow key or the left arrow key to vary the manual AGC
level for best reception.
Push the ENT key to accept the data and return to a standard display. Alternatively, push the
ESC key to abort entry, or, push the down arrow key to move to the next item on the
configuration menu (IF-GAIN).
6-6 Configure IF-GAIN (Intermediate Frequency gain)
The IF gain control reduces the amplification in the receiver’s IF circuits and has the effect of
reducing the sensitivity of the receiver. Normally, this is performed by the AGC system, and
the control is left at maximum gain, but reducing the gain can be useful to limit noise when
listening to CW or SSB signals. The IF gain control must be used if the AGC is turned off.
The default setting for IF-GAIN is 255 (maximum gain control value).
To access the configuration menu, push the FUNC key and then push the 7 key.
Push the down arrow key to move the cursor to the “IF-GAIN” selection point.
Use the main tuning dial, the right arrow key or the left arrow key to vary the IF-Gain