Specifications
28
Push either the right arrow key or left arrow key to select the desired memory bank.
Rotate the main tuning dial or push either the up arrow key or down arrow key to select
the desired memory channel to delete.
Push the ENT key to delete it or push ESC to abort.
4 SCAN – scanning memory channels
In the SCAN mode the contents stored in the memory channels are automatically recalled
and scanned very quickly for activity.
*** It is important that you do not confuse SCAN and SEARCH modes. ***
SEARCH mode (covered later in this manual) automatically TUNES THE RECEIVER
THROUGH ALL FREQUENCIES between two specified frequency limits looking for active
frequencies.
4-1 SCAN – outline introduction
During SCAN, the AR-ONE automatically recalls memory channels which contains data in
numeric order and monitors them looking for activity. When an ‘active’ memory channel is
located (when a signal is found and the squelch is open), the AR-ONE will temporarily stop
scanning.
4-2 Starting SCAN
Presuming that some memory channels are programmed with data, start the scan
process with one push of the SCAN key.
The icon “HYPER SCAN” is displayed on the LCD to indicate that the SCAN process has
been started, a bank number will be also be displayed representing the current bank.
Ensure that the squelch is set to threshold point so that background noise is
cancelled and the squelch closes (otherwise scan will not operate).