Command : WUMC Function : SET MARKER FREQ. AS RECEIVE FREQ.
Command category: WRITE
Parameter : N/A
Example : WUMC<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: This command is not available for the Other (10M) or Other (45M) receiver.
Command : WUDS Function : MOVE MARKER POSITION Command category: WRITE
Parameter : 1 ~ 2
Example : WUDS2<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = 1 step left, 2 = 1 step right Data entry for out of range will respond by
?<CR><LF>, and the command will be ignored.
Command : WUOM Function : SET MONITOR MODE Command category: WRITE
Parameter : 1 ~ 3
Example : WUOM1<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = Spectrum analyzer mode, 2 = StepReso. mode, 3 = Channel mode
Data entry for out of range will respond by ?<CR><LF>, and the command will be ignored.
Command : RUOM Function : READ MONITOR MODE Command category: READ
Parameter : N/A
Example : RUOM<CR><LF> Response: UOM1<SP><CR><LF>
Remarks: Parameter: 1 = Spectrum analyzer mode, 2 = StepReso. mode, 3 = Channel mode
Command : WUCS Function : PROGRAM CHANNEL MODE Command category: WRITE
Parameter : 3 parameter entry
Example : WUOS 79.5 10 81.1<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Enter START freq. and END freq. in MHz, and STEP freq. in KHz. Enter the <SP>
(Space) between each parameter. Data entry for out of range will respond by ?<CR><LF>, and the
command will be ignored.
Command : RUCS Function : READ CHANNEL MODE Command category: READ
Parameter : N/A
Example : RUCS<CR><LF> Response: USCS 79.5 10 81.1<SP><CR><LF>
Remarks: Respond START freq. and END freq. in MHz, and STEP freq. in KHz. There is space
between each parameter.
Command : WUBP Function : SET BEEP ON/OFF Command category: WRITE
Parameter : 1 ~ 2
Example : WUBP1<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = BEEP ON, 2 = BEEP OFF
Command : RUBP Function : READ BEEP ON/OFF Command category: READ
Parameter : N/A
Example : RUBP<CR><LF> Response: UBP1<SP><CR><LF>
Remarks: Parameter: 1 = BEEP ON, 2 = BEEP OFF