Specifications
44
User interface
Command : WUMD Function : SET RECEIVER MODE Command category: WRITE
Parameter : 1 ~ 15
Example : WUMD1<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = WFM, 2 = NFM, 3 = SFM, 4 = WAM, 5 = AM, 6 = NAM, 7 = LSB,
8 = USB, 9 = CW, 10 = AUTO, 11 = AMW, 12 = FM, 13 = FMN, 14 AMN, 15 = CWN
Data entry for out of range or any mode that is not supported by the associated receiver will respond
by ?<CR><LF>, and the command will be ignored
Command : RUMD Function : READ RECEIVER MODE Command category: READ
Parameter : N/A
Example : RUMD<CR><LF> Response: UMD1<SP><CR><LF>
Remarks: Parameter: 1 = WFM, 2 = NFM, 3 = SFM, 4 = WAM, 5 = AM, 6 = NAM, 7 = LSB,
8 = USB, 9 = CW, 10 = AUTO, 11 = AMW, 12 = FM, 13 = FMN, 14 AMN, 15 = CWN
Command : WUAT Function : SET ATT Command category: WRITE
Parameter : 1 ~ 2
Example : WUAT2<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = ON, 2 = OFF Data entry for out of range or the attenuator function is not
supported by the associated receiver, the SDU5600 will respond by ?<CR><LF>, and the command
will be ignored
Command : RUAT Function : READ ATT MODE Command category: READ
Parameter : N/A
Example : RUAT<CR><LF> Response: UAT2<SP><CR><LF>
Remarks: Parameter: 1 = ON, 2 = OFF
Command : WUST Function : SET STEP FREQ. Command category: WRITE
Parameter : Size in KHz
Example : WUST12.5<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Data entry for out of range or if the input freq. step is not supported by the associated
receiver, the SDU5600 will respond by ?<CR><LF>, and the command will be ignored
Command : RUST Function : READ STEP FREQ. Command category: READ
Parameter : N/A
Example : RUST<CR><LF> Response: UST12.5<SP><CR><LF>
Remarks: Size in KHz
Command : WURX Function : SELECT RECEIVER Command category: WRITE
Parameter : 1 ~ 10
Example : WURX3<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = Other (10M), 2 = Other (45M), 3 = AR5000, 4 = AR3000A,
5 = AR8600 (10M), 6 = AR8600 (45M), 7 = AR8200, 8 = AR-ONE, 9 = IC-R8500, 10 = IC-R7100,
11 = RFU5600 Data entry for out of range will respond by ?<CR><LF>, and the command will be
ignored.
Command : RURX Function : READ RECEIVER TYPE Command category: READ
Parameter : N/A
Example : RURX<CR><LF> Response: URX3<SP><CR><LF>
Remarks: Parameter: 1 = Other (10M), 2 = Other (45M), 3 = AR5000, 4 = AR3000A,
5 = AR8600 (10M), 6 = AR8600 (45M), 7 = AR8200, 8 = AR-ONE, 9 = IC-R8500, 10 = IC-R7100,
11 = RFU5600
Section 8-4