Command : WSTL Function : SET PEAK TRIGGER LEVEL Command category: WRITE
Parameter : -90 ~ 0
Example : WSTL-80<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Data entry for out of range will be respond by ?<CR><LF>, and the command will be
ignored.
Command : RSTL Function : READ PEAK TRIGGER LEVEL Command category: READ
Parameter : N/A
Example : RSTL<CR><LF> Response: STL-80<SP><CR><LF>
Remarks: Read the trigger level in the Peak mode.
Command : WSDM Function : SET DATA MODE Command category: WRITE
Parameter : 1 ~ 4
Example : WSDM2<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Parameter: 1 = NORMAL, 2 = AVR, 3 = MAX, 4 = MED If AVR or MED is selected, you
need to set the WSME command before executing the command. Data entry for out of range will
respond by ?<CR><LF>, and the command will be ignored.
Command : RSDM Function : READ DATA MODE Command category: READ
Parameter : N/A
Example : RSDM<CR><LF> Response: SDM3<SP><CR><LF>
Remarks: Parameter: 1 = NORMAL, 2 = AVR, 3 = MAX, 4 = MED
Command : WSAV Function : SET AVR SAMPLING Command category: WRITE
Parameter : 2 ~ 31
Example : WSAV10<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Set AVR sampling and set the DATA mode to AVR. Data entry for out of range will respond
by ?<CR><LF>, and the command will be ignored.
Command : RSAV Function : READ AVR SAMPLING Command category: READ
Parameter : N/A
Example : RSAV<CR><LF> Response: SAV10<SP><CR><LF>
Command : WSME Function : SET MED SAMPLING Command category: WRITE
Parameter : 2 ~ 4
Example : WSME4<CR><LF> Response: if correct: <SP><CR><LF>
if incorrect: ?<CR><LF>
Remarks: Set MED sampling and set the DATA mode to MED. Data entry for out of range will
respond by ?<CR><LF>, and the command will be ignored.
Command : RSME Function : READ MED SAMPLING Command category: READ
Parameter : N/A
Example : RSMED<CR><LF> Response: SMED4<SP><CR><LF>