Specifications

50
2. Select the bank link group number, and then press the [DOWN] key. The pause setting screen will
appear.
3. Rotate the sub dial to set scan pause parameter (between 1 ~ 60 or off). To set scan pause to
off (zero), press the [PASS] key or enter “0” from the numeric keypad.
4. To confirm entry, press the [MHz] key. To set other parameters, press the [DOWN] key.
7-7-3 SCAN DELAY
The scan delay parameter affects the time the AR5001D will remain on an active channel in the scan
mode once the received signal has disappeared and the squelch is closed. This is particularly useful
for customizing how long the receiver will wait for a reply before continuing to scan.
The parameter ranges are off, hold and 0.1 to 9.9 seconds.
To set the scan delay parameter, perform the following steps:
1. Press the [FUNC] key, and then press the [SCAN] key. The bank link screen will appear.
2. Select the bank link group number, and then press the [DOWN] key. The pause setting screen will
appear.
3. Press the [DOWN] key again.
4. Rotate the sub dial to select the scan delay. If “hold” is selected, the receiver will stop scanning
when the signal is received until either the [UP] key, or [DOWN] key is pressed.
5. To confirm entry, press the [MHz] key. To set other parameters, press the [DOWN] key.
7-7-4 VOICE SCAN
When the voice scan function is activated, the scan process will stop only on active channels which have
modulation (such as voice) present. The AR5001D will not remain on unmodulated channels (such as
blank carriers). The parameter ranges are off, hold and 1 ~ 7.