Specifications
36
4-4-5 Delete memory bank
MB MBnn: nn: Bank number
4-5 SCAN
4-5-1 Start scan
MS
LC
MSnn nn: Memory channel
If the memory frequency is registered to pass frequency lit, it will be skipped.
LCn: n : 0, 1
0: No report (default)
1: Output detected frequency information
4-5-2 Memory data setting
MGnn DLnn FRnn BKxxxxxx…xxxx MG
BK
The AR2300 features 20 scan groups.
MGnn: nn: 00 ~ 19 (Scan bank number) (default: 00)
DLnn: nn: 01 ~ 99 (Squelch delay time) (in 0.1 sec.)
(between squelch closing and scan restart) (default: 20)
FRnn: nn: 00 ~ 60 (Free scan) (in 1 second)
(default: 00 Off)
(duration is how long the AR2300 will remain on
active frequency before resuming scan even when the
frequency is still active).
BKxxxxxx….xxxx: Linked bank number
(Example: Link 02 05 11, then BK020511.
(Note: Scan bank 00 cannot be linked.)
To delete bank, enter BK<CR>.
Note: The DL, FR, BK commands cannot be used alone.
They must always be used in conjunction with the MG command.
To read: MGnn<CR>
Response: MGnn DLnn FRnn BKxxxxxx…xxxx
4-5-3 Memory pass
MP
MPn: n: 0, 1
0: Pass Off
1: Pass
MPnn: nn: 00 ~ 39 (memory bank)
Memory pass cancel on the selected bank
To read: MP<CR>
Response: MPn