Specifications
71
LM To read: LM <CR>
NSQm LMnnn --- When the noise squelch is selected
(nnn: 000 – 999)
LSQm LMnnn --- When the level squelch is selected
(nnn: 000 – 999)
m: 1 when the squelch is closed
Response
m: 0 when the squelch is opened
7-3-22 AUTO SIGNAL LEVEL
LC
LCn (n: 0 or 1)
n:0 Auto Signal Level off
n:1 Auto Signal Level on
While n is set to 1, and the squelch is opened, a signal level and frequency data
will be sent
LSQm LMnnn --- When the level squelch is selected
(nnn: 000 – 999)
m: 1 when the squelch is closed
m: 0 when the squelch is opened
To read: LC <CR>
LCn
SQm LCnnn RFnnnnnnnnnn
Response:
m: 0 Noise squelch mode
m: 1 Level squelch mode
7-3-23 AUTO BACKLIT
LAn (n: 0 - 2)
n: 0 LAMP OFF
n: 1 LAMP ON (Default)
LA
n: 2 LAMP AUTO
(Will go off in 5 seconds after the squelch is closed)
To read: LA<CR>
Response: LAn
7-3-24 BACKLIT ON/OFF