Specifications

65
PARITY: NONE
XFLOW: ONE
A multiple command entry is only valid where specified. Where a multiple command entry is
allowed, each command MUST be separated with a space “h20” (HEX DECIMAL). Each
command is completed and a [CR] or [CR][LF]. Although there is no local echo, either [CR]
or specified response should come back from the receiver after confirming the correct
command. If no response has been gained after a short while, the receiver has failed to
receive the command properly. Send a [CR] then re-send the command. Should problem
persist, check your connections and try reducing the RS-232C baud rate.
7-2 Power on the AR-ONE
Connect an RS-232C cable between the AR-ONE and a PC, type any key to power up the
AR-ONE.
7-3 Detailed RS-232C command listing of the AR-ONE
X
Power on
x: any key to power on the AR-ONE
QP
Power off
Power off
^Ann
Remote ON
Hex value 0x01
Accept a value nn in the range of 00-99 for remote
connection
EX
Remote off
Remote off
IDnn
Remote ID
To set: IDnn<CR> nn: 00-99
To read:ID<CR>
7-3-1 RX MODE
Vx
Select VFO
To set: Vx<CR> x:A – J (default :A)
MRmnn
Memory mode
m: 0 – 9 (memory bank) n: 00 – 99 (memory
channel)
(default: 000)
MSm
Memory scan mode m: 0 – 9 (memory bank) (default: 000)
SM
Memory select
mode
SSmm
Search mode mm: 01 – 40 (search bank) (default: 01)