User Manual

Range
Accuracy
Resolution
400Ω
1.5% of rdg+15 digits
0.1Ω
4kΩ
1.2% of rdg+15 digits
40kΩ
10Ω
400kΩ
100Ω
4MΩ
1kΩ
40MΩ
2.5% of rdg+15 digits
10kΩ
Overload protection: 250V DC/250Vrms AC
2.2.6 Capacitance
Range
Accuracy
Resolution
51.2nF
6.0% of rdg+10 digits
10PF
512nF
3.5% of rdg+5 digits
100PF
5.12μF
1nF
51.2μF
10nF
100μF
6.0% of rdg+10 digits
100nF
Overload protection: 250V DC/250Vrms AC
2.2.7 Frequency
Range
Accuracy
Resolution
Sensitivity
5.12Hz
1.2% of rdg+10 digits
0.001Hz
Range of input
voltage:1.5V~10V
If input voltage over
range,adjustment is
needed.
51.2Hz
0.01Hz
512Hz
0.8% of rdg+5 digits
0.1Hz
5.12kHz
1Hz
51.2kHz
10Hz
512kHz
100Hz
5.12MHz
2.0% of rdg+10 digits
1kHz
Overload protection: 250V DC/250Vrms AC
Duty cycle: 0.1%99.9%
2.2.8 Temperature(NiCr-NiSi sensor)
Range
Accuracy
Resolution
-20150
3+2
1
150300
3.0% of rdg+2 digits
1
3001000
3.5% of rdg+10 digits
1
Overload protection: 250V DC/250Vrms AC
2.2.9 Diode and Audible continuity test
Range
Description
Test condition
Display read approx.
Forward voltage of diode.
Forward DC current
approx. 0.4mA
Reversed DC voltage
approx. 1.5V
Built-in buzzer sounds
if resistance is less
than 90Ω
Open circuit voltage
aprox. 0.5V