Installation and Operation of 20 Minute and 20/40/60 Minute Timers
Operating your Lifestyle 20 Minute or 20/40/60
Minute Timers
Press and release the Select Button to activate high speed
override. The High Speed Status Light illuminates and the
unit runs on high speed ventilation for 20 minutes.
The Lifestyle 20/40/60 Minute timers provide an extended
override time of 20 - 40 additional minutes by pressing and
releasing the Select button.
The High Speed Status Light dims after 10 seconds of run
time.
The High Speed Status Light flashes during the last
5 minutes of the cycle.
All timers connected to the unit illuminate for the duration of
the override when the Select button is pressed.
Lockout Mode
Lockout Mode is useful for disabling the timers.
The timer can be set to lockout mode by pressing and
holding the Select button for five seconds. After five
seconds, the High Speed Status Light flashes; release the
Select button. The timer is now in lockout mode. If the Select
button is pressed during lockout mode, the High Speed
Status Light momentarily illuminates; however, no override is
initiated.
If lockout mode is initiated when the timer is activated, the
timer continues its timed sequence; however, no further
overrides are initiated. Lockout mode can be unlocked by
pressing and holding the Select button for five seconds. After
five seconds the High Speed Status Light stops flashing.
Release the Select button. The timer will now operate
normally.
Terminal Block Connections
(from Timer to Terminal Block)
Yellow on timer to YELLOW #4
Red on timer to RED #3
Green on timer to GREEN #5
Red #3
Yellow #4
Green #5
High Speed
Status Lights
Select Button
initiates high speed
ventilation for 20, 40
or 60 minutes.
Yellow
Red
Green
NOTE ABOUT TIMERS
• Timers mount in standard 2” x 4” electrical boxes.
• Wire multiple timers individually back to the unit.
• Use 3/20 low voltage wire