Installation manual
STALE AIR
TO OUTSIDE
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FRESH AIR
TO INSIDE
14
3
/4"
(375)
19"
(483)
*All Duct Connections 6"(150mm)
FILTERS
BLOWERS
*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for servicing unit.
MOTOR
ENTHALPIC CORE
33-5/8"
(850)
BALANCING
DAMPER
BALANCING
DAMPER
CORE
Model 200ERV
DIMENSIONS 200ERV inches (mm)
info@lifebreath.com
T 1-855-247-4200
F 1-800-494-4185
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
All units conform to CSA and UL standards.
Static Pressure (in w.g.)
Air Flow (cfm)
20
40
60
80
100
120
140
160
180
200
220
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
3 - Medium Speed
2 - Medium Low Speed
1 - Low speed
4 - High Medium Speed
5 - High Speed
Speed 5
Speed 4
Speed 3
Speed 2
Speed 1
*Sensible Efficiency – thermal
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs
Performance (HVI Certified)
Net supply air flow in cfm (L/s) against external static pressure
E.S.P
(external static pressure) [cfm (L/s)]
@ 0.1" (25 Pa) 180 (85)
@
0.2" (50 Pa) 169 (80)
@ 0.3" (75 Pa) 157 (74)
@
0.4" (100 Pa) 146 (69)
@ 0.5" (125 Pa) 132 (62)
@ 0.6" (150 Pa) 118 (56)
@ 0.7" (175 Pa) 101 (48)
Sensible Effectiveness
@ 116 cfm (55 L/s) 32°F (0°C) 76%
*Sensible Efficiency
@ 116 cfm (55 L/s) 32°F (0°C) 69%
T
otal Efficiency 50%
V
AC @ 60HZ 120
W
ATTS / Low speed 68
WATTS / High speed 97
Amp rating 1.4
ENGINEERING DATA
LATENT RECOVERY/MOISTURE TRANSFER CORE
The counter-flow energy recovery core transfers heat and water vapor between the
two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
Four threaded inserts at corners of the cabinet designed to accept the “S” hooks and
hanging straps supplied with the unit.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance.
Insulated to prevent exterior condensation. Door balancing ports.
WEIGHT 75 lbs. (34Kg) SHIPPING WEIGHT 77lbs. (35Kg)
DEFROST—not available on this model
CONTROLS & ELECTRONICS
The Lifestyle Digital Control (included with unit) can be wall mounted in a central
location of the home. (3 wire) 20 gauge wire (min.) 100' length
Electronic features include:
• 5 Speed Operation on each mode
• 2 user selectable operational modes: Continuous Ventilation, 20 ON/40 OFF
• Built-in Relay for Interfacing to furnace
• Service Reminder
• 20, 40, 60 minute Override Timer
• Dehumidistat Disable Feature
OPTIONAL PROGRAMMABLE CONTROL
99-LS01 Lifestyle Programmable Control - contains all the features of the
Lifestyle Digital Control with 7/24 programmable ventilation,
(3 wire) 20 gauge wire (min.) 100' length
OPTIONAL TIMERS
99-DET01 Lifestyle 20/40/60 Minute Timer - Initiates high speed ventilation for
20, 40, or 60 minutes. (3 wire) 20 gauge wire (min.) 100' length
99-20M01 Lifestyle 20 Minute Timer - Initiates high speed ventilation for
20 minutes, (3 wire) 20 gauge wire (min.) 100’ length.
OPTIONAL ACCESSORIES
99-186 Weatherhood Kit, Two — 6” (150 mm), labelled Supply & Exhaust,
c/w sleeve, collar, 1/4” (6 mm) mesh screen
WARRANTY
Units carry a tem (10) year warranty
on the enthalpic (ERV) core and a five
(5) year replacement parts warranty.
10