Specifications
Key switch operation for device.
4
Delayed Egress Mode: Unit is armed and touch bar will not activate the latchbolt. (LED is solid green,
audible alarm is off). Initiated after power up, (DIP switch #2 in OFF position) authorized egress mode
or re-arm mode.
Nuisance Alarm Mode: Unit is armed and touch bar will not activate the latch bolt. (LED is solid green,
audible alarm sounds a short tone) DIP switch selectable for 1 or 3 seconds. (See page 2) Initiated by
depressing touch bar.
Delay Mode: Unit is armed and touch bar will not activate the latch bolt. (LED is solid yellow, audible alarm
sounds intermittent tone). Unit remains in the delay mode for 15 seconds ( including nuisance time).
Initiated by holding the touch bar depressed past the nuidance alarm time (30 second delay mode option
available.) Once started, the delay mode is irreversible and automatically initiates the alarm mode.
Alarm Mode: Unit is disarmed and touch bar will activate the latch bolt (LED is solid red, audible alarm
sounds continous tone). Initiated automatically from the delay mode and is irreversible. Unit remains in
the alarm mode until manually reset with key.
By-Pass Mode: From the delayed egress mode; unit is continuously disarmed and touch bar will activate
the latch bolt (LED slowly flashes green, audible alarm is off). Initiated by rotating the key clockwise until
switch activates (approximately 180 degrees). DPS input is disabled.
Re-arm Mode: From alarm mode; unit goes to the delayed egress mode. Initiated by rotating the key
clockwise until switch activates (approximately 180 degrees). From the bypass mode; unit goes to the
delayed egress mode. Initiated by rotating the key clockwise until the switch activates (approximately
180 degrees.) The LED will return to solid green.
Authorized Egress Mode: Unit is disarmed for 10 or 20 seconds (DIP switch selectible) and touch bar
will activate the latch bolt (LED quickly flashes green, audible alarm is off). After the authorized egress
time unit returns to the delayed egress mode automatically. The authorized egress mode is initiated by
rotating the key counter-clockwise until switch activates (approximately 180 degrees). DPS input will not
initiate during the 10 or 20 second egress time, but will terminate the egress time if the DPS closes
before the end of the egress time. DPS input will initiate an alarm after the 10 or 20 second egress time,
if the DPS is opened.
NOTE: The By-pass mode and Re-arm mode (orange wire) may be intiated externally from the terminal
connector. (Normally open dry contact to ground.) The Authorized Egress mode (white wire) may be
initiated externally from the terminal connector (Normally open dry contact to ground). See page 6 for
addtional details.
Bypass/Re-arm
Authorized Egress
Rotate Clock-wise
Rotate Counter Clock-wise