Service manual

Instrument Functions WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
88Operating Manual 1176.7649.02 ─ 04
4.2.1 General Settings
Standard .......................................................................................................................88
Frequency .................................................................................................................... 88
Channel No .................................................................................................................. 88
Signal Level / Reference Level..................................................................................... 88
Auto Lvl ..........................................................................................................89
Ext Att ...........................................................................................................................89
Capture Time ............................................................................................................... 89
PPDU Count .................................................................................................................89
Analyze PPDUs ............................................................................................................89
Sweep Count ................................................................................................................90
Trigger Mode ................................................................................................................90
Trigger Offset ............................................................................................................... 90
Trigger Holdoff.............................................................................................................. 90
Trigger Hysteresis.........................................................................................................91
Ext. Trigger Lvl..............................................................................................................91
Power Level ................................................................................................................. 91
Auto Lvl ..........................................................................................................91
Input.............................................................................................................................. 91
Standard
Displays a list of all installed standards to select the wireless LAN standard. This is
necessary to ensure that the measurements are performed according to the specified
standard with the correct limit values and limit lines.
Remote command:
CONFigure:STANdard on page 154
Frequency
Specifies the center frequency of the signal to be measured. If the frequency is modi-
fied, the "Channel No" field is updated accordingly.
Remote command:
[SENSe:]FREQuency:CENTer on page 197
Channel No
Specifies the channel to be measured. If the "Channel No" field is modified, the fre-
quency is updated accordingly.
Remote command:
CONFigure:CHANnel on page 153
Signal Level / Reference Level
Specifies the expected mean level of the RF input signal. If an automatic level detec-
tion measurement has been executed the signal level (RF) is updated.
General Settings Dialog Box (K91)