Service manual
Instrument Functions WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
82Operating Manual 1176.7649.02 ─ 04
When using "ETSI" or "IEEE" standards, "File Name" indicates the name of the built-in
configuration.
Remote command:
MMEMory:LOAD:SEM:STATe 1, on page 180
Trace Reduction ← SEM Settings ← Spectrum
During the Spectrum Emission Mask (SEM) measurement data is acquired and trace
data is selected according to the trace detector setting from the SEM xml definition file
for each frequency range. Alternatively, the peak detector can be used regardless of
the setting in the SEM definition file.
"Peak"
For each frequency range, the peak detector is used to determine the
corresponding trace value. This was the behaviour for the SEM mea-
surement in R&S FSV-K91 versions before 1.70.
"Trace detec-
tor"
For each frequency range, the trace detector defined in the SEM xml
file is used to determine the corresponding trace value.
Remote command:
[SENSe:]POWer:SEM:TRACe:REDuction on page 200
TX Channel ← SEM Settings ← Spectrum
The bandwidth and RBW of the transmission channel are displayed for reference only.
SEM Configuration ← SEM Settings ← Spectrum
The table shows the settings and limits applied over specified frequency ranges around
the TX channel.
Chan Sel ← Spectrum
Selects the channel model for the Spectrum Flatness measurement.
"Effective"
The composition of the physical channel and the MIMO encoder.
"Physical"
Physical channel
Remote command:
CONFigure:BURSt:SPECtrum:FLATness:CSELect on page 151
Import ← Spectrum
See "Import" on page 68.
Export ← Spectrum
See "Export" on page 68.
R&S Support ← Spectrum
See "R&S Support" on page 69.
Statistics
Opens a submenu to display statistics measurement results.
Settings General/Demod ← Statistics
See "Settings General/Demod" on page 64
Softkeys of the WLAN TX Menu