Service manual

WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
42Operating Manual 1176.7649.02 ─ 04
Fig. 3-9: Mixed mode 20MHz signal with "Channel BW to measure" set to measure only 40MHz sig-
nals
Messages and warnings
The following messages are generated by the R&S FSV-K91 measurement applica-
tion:
Results contribute to overall results despite inconsistencies:
"Info: Comparison between HT-SIG Payload Length and Estimated Payload
Length not performed due to insufficient SNR"
The R&S FSV-K91 application compares the HT-SIG length against the length estima-
ted from the PPDU power profile. If the two values do not match, the corresponding
entry is highlighted orange. If the signal quality is very bad, this comparison is sup-
pressed and the message above is shown.
"Warning: HT-SIG of PPDU was not evaluated"
Decoding of the HT-SIG was not possible because there was to not enough data in the
Capture Memory (potential burst truncation).
"Warning: Mismatch between HT-SIG and estimated (SNR+Power) PPDU length"
The HT-SIG length and the length estimated by the R&S FSV application (from the
PPDU power profile) are different.
"Warning: Physical Channel estimation impossible / Phy Chan results not availa-
ble Possible reasons: channel matrix not square or singular to working preci-
sion"
Signal Field Measurement (IEEE 802.11ac, n (SISO+MIMO))