Service manual
WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
40Operating Manual 1176.7649.02 ─ 04
● The second line shows the R&S FSV-K91 parameters affecting which PPDUs take
part in the analysis and which do not (this functionality is referred as "logical filter").
●
The value inside the white rectangle indicates the current "logical filter" setting.
Fig. 3-7: FSV-K91 Enhanced Signal Field measurement
Measurement settings
The settings for this measurement are defined in the "Demod Settings" for the IEEE
802.n standard, and in the "Advanced Demod Settings" for the IEEE 802.n (MIMO)
standard.
Note that for the IEEE 802.n standard, the "Use Signal Field Content" setting must be
activated for Signal Field measurements.
The following table indicates which PPDU properties are displayed in the result table of
the Signal Field measurement and which R&S FSV-K91 settings are used to obtain
these properties.
PPDU Property Setting for IEEE 802.n Setting for IEEE 802.n (MIMO)
Format PPDU Frame Format Burst type to measure
MCS Auto Demod ON: Auto, same type as first burst
Auto Demod OFF:PSDU Mod to Analyze
MCS Index to use
Bandwidth PPDU Frame Format Channel BW to measure
HT Length Source of Payload Len Source of Payload Len
GI Guard Interval Guard Interval Len
Signal Field Measurement (IEEE 802.11ac, n (SISO+MIMO))