Service manual

Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
227Operating Manual 1176.7649.02 ─ 04
Bit No. Meaning
6 Auto level NoSIGnal
This bit is set if no signal is detected by the auto-level measurement
7 - 14 These bits are not used.
15 This bit is always 0.
5.19.5 STATus:QUEStionable:ACPLimit Register
This register contains information about the observance of limits during adjacent power
measurements. It can be read using the commands STATus:QUEStionable:
ACPLimit:CONDition and STATus:QUEStionable:ACPLimit[:EVENt].
No limit lines are displayed in screen A.
Table 5-9: Meaning of the bits used in the STATus:QUEStionable:ACPLimit register
Bit No. Meaning
0 - 7 Not used
8 ADJ UPPer FAIL (Screen B)
This bit is set if the limit is exceeded in the upper adjacent channel in screen B
9 ADJ LOWer FAIL (Screen B)
This bit is set if the limit is exceeded in the lower adjacent channel in screen B.
10 ALT1 UPPer FAIL (Screen B)
This bit is set if the limit is exceeded in the upper 1st alternate channel in screen B.
11 ALT1 LOWer FAIL (Screen B)
This bit is set if the limit is exceeded in the lower 1st alternate channel in screen B.
12 ALT2 UPPer FAIL (Screen B)
This bit is set if the limit is exceeded in the upper 2nd alternate channel in screen B.
13 ALT2 LOWer FAIL (Screen B)
This bit is set if the limit is exceeded in the lower 2nd alternate channel in screen B.
14 Not used
15 This bit is always 0.
Status Reporting System (Option R&S FSV-K91)