Service manual

WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
21Operating Manual 1176.7649.02 ─ 04
13. Using the "Graphics | Power Spectrum" display shows the power spectrum for both
antennas.
14.
Now set up the spectrum analyzer with the R&S FSV-K91n option to perform the
WLAN MIMO measurements. Start the R&S FSV-K91n application.
15. Select "Standard" IEEE 802.11n (MIMO).
Set the "RF Frequency" the DUT is transmitting.
16. Set "Trigger Mode" to "External".
Select the "STC/MIMO" tab in the "General Settings" dialog box.
17. Select "DUT MIMO configuration" 2 Tx Antennas.
18. Set the "IP Address" of the slave in the "MIMO Measurement Setup" table and turn
the "State" of the slave to ON.
3.3 Signal Processing of the IEEE 802.11a Application
This description gives a rough view of the IEEE 802.11a application signal processing.
Details are disregarded in order to get a concept overview.
Signal Processing of the IEEE 802.11a Application