Service manual

Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
190Operating Manual 1176.7649.02 ─ 04
Parameters:
<State> ON | OFF
*RST: OFF
Example:
DEM:FORM:BAN:DBYTes:EQU ON
Only bursts of equal length will take part in the measurement
analysis.
Mode: WLAN
Manual operation: See "Equal PPDU Length" on page 100
[SENSe:]DEMod:FORMat:BANalyze:DBYTes:MAX <NumberDataBytes>
This command specifies the maximum number of data bytes required for bursts to
qualify for measurement analysis. Only bursts with the specified number of data bytes
will be used in the measurement analysis.
This value will not have any immediate effect if the [SENSe:]DEMod:FORMat:
BANalyze:DBYTes:EQUal on page 189 command has been set to ON. In this case,
no range of symbols is allowed and only bursts with exactly the number of data bytes
specified by the [SENSe:]DEMod:FORMat:BANalyze:DBYTes:MIN on page 190
command shall take part in measurement analysis.
Parameters:
<NumberDataBytes> *RST: 64
Example:
DEM:FORM:BAN:DBYTes:MAX 1300
Only bursts which contain a maximum of 1300 data bytes are
analyzed.
Mode: WLAN
Manual operation: See "Max Payload Length (IEEE 802.11b, g)" on page 102
[SENSe:]DEMod:FORMat:BANalyze:DBYTes:MIN <NumberDataBytes>
This command specifies the number of data bytes required for bursts to qualify for
measurement analysis. Only bursts with the specified number of data bytes will be
used in the measurement analysis.
If the [SENSe:]DEMod:FORMat:BANalyze:DBYTes:EQUal on page 189 command
has been set to ON, this command specifies the exact number of data bytes required
for a burst to take part in measurement analysis. If the [SENSe:]DEMod:FORMat:
BANalyze:DBYTes:EQUal on page 189 command is set to OFF, this command
specifies the minimum number of data bytes required for a burst to take part in mea-
surement analysis.
Parameters:
<NumberDataBytes> *RST: 1
Example:
DEM:FORM:BAN:DBYTes:MIN 16
Only bursts which contain 16 data bytes are analyzed.
SENSe Subsystem (WLAN)