Service manual
Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
168Operating Manual 1176.7649.02 ─ 04
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RLEVel:OFFSet <Value>
This command specifies the external attenuation/gain applied to measurements. The
value corresponds to the reference level offset in the spectrum analyzer mode.
Suffix:
<n>
.
1 | 2
irrelevant
<t> 1...3
irrelevant
Parameters:
<Level> <numeric value> in dB
*RST: 0 dB
Example:
DISP:TRAC:Y:RLEV:OFFS 10
External attenuation (level offset) of the analyzer is 10 dB.
DISP:TRAC:Y:RLEV:OFFS -10
External attenuation of the analyzer is -10 dB. i.e. a gain of 10
dB.
Mode: WLAN
5.8 FETCh Subsystem (WLAN)
The FETCh subsystem contains commands for reading out results of complex mea-
surement tasks. This subsystem is closely linked to the CONFigure and SENSe sub-
systems.
5.8.1 ASCII formats for returned values...............................................................................168
5.8.2 Commands of the Fetch Subsystem (K91)................................................................. 169
5.8.1 ASCII formats for returned values
The results are output as a list of result strings separated by commas.
Returned values for IEEE 802.11a, j, g(OFDM), n, p & Turbo Mode
<preamble power>, <payload power>, <min rms power>,
<average rms power>,<max rms power>, <peak power>,
<min crest factor>,<average crest factor>,<max crest factor>,
<min frequency error>,<average frequency error>, <max frequency error>,
<min symbol error>, <average symbol error>, <max symbol error>,
<min IQ offset>, <average IQ offset>, <maximum IQ offset>,
<min gain imbalance>, <average gain imbalance>, <max gain imbalance>,
<min quadrature offset>, <average quadrature offset>, <max quadrature offset>,
FETCh Subsystem (WLAN)