Service manual

Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
165Operating Manual 1176.7649.02 ─ 04
Suffix:
<n>
.
1 | 2
window; 1=A, 2=B
Parameters:
*RST: 1
Example:
DISP:WIND1:SSEL
Sets the screen A active.
Mode: WLAN
Manual operation: See "Screen Focus A/B" on page 111
DISPlay[:WINDow<n>]:TABLe <State>
This command selects whether the results table is displayed.
Suffix:
<n>
.
1 | 2
window; 1=A, 2=B
Parameters:
<State> ON | OFF
*RST: ON
Example:
DISP:WIND1:TABL ON
Hides the results table
Mode: WLAN
Manual operation: See "Display List/Graph" on page 64
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:AUTO <State>
This command switches on or off automatic scaling of the Y-axis for the specified trace
display. Automatic scaling sets the Y-axis to automatically scale to best fit the mea-
surement results. This command is only available for the following result displays:
EVM vs Carrier
EVM vs Symbol.
Frequency error vs Preamble
Phase error vs Preamble
Suffix:
<n>
.
2
window; must be 2 as the relevant results are always displayed
in screen B
<t> 1
trace; must be 1
DISPlay Subsystem (WLAN)