Service manual
Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
154Operating Manual 1176.7649.02 ─ 04
CONFigure:POWer:AUTO:SWEep:TIME <Time>
This remote control command is used to specify the sweep time for the automatic
power level detection.
Parameters:
<Time> numeric value in seconds
*RST: 100ms
Example:
CONF:POW:AUTO:SWE:TIME 200MS
Configures a 200 ms sweep time for the auto-level detection.
Mode: WLAN
Manual operation: See "Auto Lvl " on page 89
See "Auto Level Time " on page 92
CONFigure:POWer:EXPected:RF <Level>
This remote control command is used to specify the mean power level of the source
signal as supplied to the Analyzer RF input. This value will be overwritten if Auto Level
is turned on.
Parameters:
<Level>
Example:
CONF:POW:EXP:RF 9
Assumes an input signal strength of 9 dBm.
Mode: WLAN
Manual operation: See "Signal Level / Reference Level" on page 88
CONFigure:POWer:EXPected:IQ <Level>
This remote control command is used to specify the mean power level of the source
signal as supplied to the optional Digital Baseband Interface (R&S FSV-B17). This
value will be overwritten if Auto Level is turned on.
Parameters:
<Level>
Example:
CONF:POW:EXP:IQ 9 MV
Assumes an input signal strength of 9 mV.
Mode: WLAN
CONFigure:STANdard <Standard>
This remote control command specifies which Wireless LAN standard the option is
configured to measure.
For details on supported standards see chapter 3.1, "Introduction to WLAN 802.11A,
AC, B, G, J, N & P TX Tests", on page 12.