Service manual
Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
153Operating Manual 1176.7649.02 ─ 04
Mode: WLAN
Manual operation: See "CCDF" on page 83
CONFigure:BURSt:STATistics:SFIeld[:IMMediate]
This remote control command configures the measurement type to be Signal Field.
After this command has been executed, the specified measurement will only be started
when the user issues the INITiate<n>[:IMMediate] command.
Example:
CONF:BURS:STAT:SFIeld
Configures the Signal Field measurement type.
Mode: WLAN
Manual operation: See "Signal Field (IEEE 802.11a, ac, g (OFDM), j , n, p)"
on page 85
See "PLCP Header (IEEE 802.11b, g – Single Carrier)"
on page 86
CONFigure:CHANnel <Channel>
This remote control command is used to specify the input channel for which measure-
ments are to be performed. This command will automatically cause the internal mea-
surement frequency to be re-calculated.
Parameters:
<Channel> *RST: 0
Example:
CONF:CHAN 9
Specifies channel 9 as frequency measurement.
Mode: WLAN
Manual operation: See "Channel No " on page 88
CONFigure:POWer:AUTO <Mode>
This remote control command is used to switch on or off automatic power level detec-
tion. When switched on, power level detection is performed at the start of each mea-
surement sweep.
Parameters:
<Mode> ONCE | ON | OFF
If this command is issued with the ONCE parameter then the
auto level routine is performed immediately one time.
Example:
CONF:POW:AUTO ON
Configures the automatic detection of the input power level.
Mode: WLAN
Manual operation: See "Auto Lvl " on page 89
See "Auto Level" on page 110
CONFigure Subsystem (WLAN)