Service manual
Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
150Operating Manual 1176.7649.02 ─ 04
Parameters:
<Mode> EDGE
configures the measurement to be rising and falling edge
FALL
configures the measurement to be falling edge only (IEEE
802.11b & g (CCK))
FULL
configures the measurement to be full burst ( IEEE 802.11a, j &
g (OFDM) n, p, IEEE 802.11 Turbo Mode)
RISE
configures the measurement to be rising edge only ( IEEE
802.11b & g (CCK))
Example:
CONF:BURS:PVT:SEL FULL
Interprets the measurement results as full burst
Mode: WLAN
Manual operation: See "Full Burst" on page 65
See "Rising & Falling" on page 65
See "Ramp Up/Down/Up & Down (IEEE 802.11b, g – Single
Carrier)" on page 66
CONFigure:BURSt:SPECtrum:ACPR[:IMMediate]
This remote control command configures the measurement type to be ACPR (adjacent
channel power relative). After this command has been executed, the specified mea-
surement will only be started when the user issues the INITiate<n>[:IMMediate]
command.
Example:
CONF:BURS:SPEC:ACPR
Configures the ACPR measurement type.
Mode: WLAN
Manual operation: See "Spectrum ACPR (IEEE 802.11a, ac, g (OFDM Turbo
Mode), n, p)/ Spectrum ACP (IEEE 802.11b)/ ACP Rel/Abs
(IEEE 802.11j)" on page 80
CONFigure:BURSt:SPECtrum:FFT[:IMMediate]
This remote control command configures the measurement type to be FFT (Fast Four-
ier Transform). After this command has been executed, the specified measurement will
only be started when the user issues the INITiate<n>[:IMMediate] command.
Example:
CONF:BURS:SPEC:FFT
Configures the FFT measurement type.
Mode: WLAN
Manual operation: See "Spectrum FFT" on page 79
CONFigure Subsystem (WLAN)