Service manual

Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
144Operating Manual 1176.7649.02 ─ 04
5.5.2
CALCulate:MARKer:FUNCtion Subsystem (WLAN, R&S FSV-
K91/91n)
The measurement window is selected by CALCulate 1 (screen A) or 2 (screen B).
CALCulate<n>:MARKer<1>:FUNCtion:POWer:RESult[:CURRent]?.................................... 144
CALCulate<n>:MARKer<1>:FUNCtion:POWer:RESult:MAXHold?...................................... 144
CALCulate<n>:MARKer<1>:FUNCtion:ZOOM...................................................................145
CALCulate<n>:MARKer<1>:FUNCtion:POWer:RESult[:CURRent]?
This command queries the current result values of the adjacent channel power mea-
surement. An ACPR (Adjacent channel power relative) measurement must have previ-
ously been run, for there to be summary data available.
Results are output separated by commas in the following order:
Power of main channel
Power of lower adjacent channel
Power of upper adjacent channel
Power of lower alternate adjacent channel 1
Power of upper alternate adjacent channel 1
Power of lower alternate adjacent channel 2
Power of upper alternate adjacent channel 2
Adjacent channel power values are output in dB.
Suffix:
<n>
.
1...4
irrelevant
Example:
CALC:MARK:FUNC:POW:RES?
Usage: Query only
Mode: WLAN
Manual operation: See "Spectrum ACPR (IEEE 802.11a, ac, g (OFDM Turbo
Mode), n, p)/ Spectrum ACP (IEEE 802.11b)/ ACP Rel/Abs
(IEEE 802.11j)" on page 80
CALCulate<n>:MARKer<1>:FUNCtion:POWer:RESult:MAXHold?
This command queries the maximum result values of the adjacent channel power mea-
surement. An ACPR (Adjacent channel power relative) measurement must have previ-
ously been run with more than one sweep, for there to be maximum summary data
available.
For details on the output refer to CALCulate<n>:MARKer<1>:FUNCtion:POWer:
RESult[:CURRent]? on page 144 .
CALCulate:MARKer Subsystem (WLAN)