Service manual
Remote Commands for WLAN TX Measurements
R&S
®
FSV-K91/91n/91ac/91p
143Operating Manual 1176.7649.02 ─ 04
●
Constellation vs Carrier
Suffix:
<n>
.
1...4
window
Parameters:
<Position> 1 to <maximum range for selected measurement>
Example:
CALC:MARK:X 2ms
Positions marker 1 in screen A to time 2ms.
Mode: WLAN, OFDMA/WiBro
Manual operation: See "Marker 1" on page 112
CALCulate<n>:
MARKer<1>:Y <Position>
This command positions the selected marker to the indicated quadrature (Constellation
vs Symbol), magnitude of I or Q (Constellation vs Carrier), EVM (EVM vs Carrier) or
abs (Spectrum Flatness) in the selected measurement window.
This command is query only for the following result displays:
●
Auto Level
●
Constellation vs Symbol
●
Constellation vs Carrier
●
EVM vs Symbol
●
PVT Full
●
PVT Rising/Falling
●
Magnitude Capture Buffer
●
Spectrum Mask
●
Spectrum ACP/ACPR
●
Spectrum FFT
●
CCDF
Suffix:
<n>
.
1...4
window
Parameters:
<Position>
Example:
CALC2:MARK:Y -2
Positions marker 1 in screen B to -2.
CALC:MARK:Y?
Outputs the measured value of marker 1.
Mode: WLAN; OFDMA/WiBro
Manual operation: See "Marker 1" on page 112
CALCulate:MARKer Subsystem (WLAN)