Specifications

Philips Fortimo HBMt Gen 3 System Design In Guide 29
ESD in the production environment
Depending on the immunity level of the LED board, there is a minimum set of
measures that have to be implemented when handling LED boards. ESD measures
are required in a production environment where handling can exceed the ESD
immunity level. Furthermore, products that are susceptible to ESD must be packed
and delivered in ESD-safe packaging.
The purpose of an effective ESD-control strategy is to reduce line failures, nal
inspection failures and eld failures.
ESD specications
Philips designed HBMt module Gen3 products to be robust when exposed to ESD.
The maximum permitted contact discharge level and air discharge level, according
to IEC 61000-4-2 (HBM 150pF + 330Ω), is 8 kV contact and 15 kV air.
Servicing and installing luminaires
It is highly recommended that installers are instructed not to touch the LED
components and to use earthed arm straps to prevent ESD damage during
installation and maintenance.
ESD consultancy
Independent ESD consultancy companies can advise and supply adequate tools and
protection guidance.
Remote system operation
Please consult the design-in guide for Xitanium LED drivers.
Use of circuit breakers: Xitanium LED drivers
Please consult the design-in guide for Xitanium LED drivers at
http://www.lighting.philips.com/us_en/connect/LED_modules/xitanium_
programmable.wpd
Cautions on use during storage, transportation and operation
• Store in a dark place
• Do not expose to sunlight
• Maintain temperature between -40 to +85° C
• Relative humidity (RH) between 5 and 85%
During operation
Fortimo LED HBMt must be operated within the specications found in
the product datasheet and design-in guide. Please contact your local sales
representative for additional information.